SETUP:
►
The test station is in the operational mode with power and ai
►
A NOREGON ADAPTOR is installed in the 1200 CERTIFIER for operation with the computer.
ABS configuration process.
1. Connect 7-way cable to trailer.
2. Click on ABS key in the GUI or on the tablet which will activate power and air (aux and
brake circuits).
3. Open the ABS program on the PC for configuration and operation of the ECU in the vehicle
under test such as Bendix or Haldex.
4. Press the SELECT key once to charge the emergency line.
·
This will enable the “Self Test” for the ECU valve.
·
This will also allow the wheels to rotate freely.
5. Press the SELECT key a second time to charge the service line.
·
This will enable the “Sensor Test” to be performed.
·
The brakes can also be cycled on and off with the tablet (or the “BRAKE” key on the
tester) while the operator spins the axles (see end-of-the-line test below).
6. Press the ABS key to cancel the ABS Test routine.
Proceed with ABS recommended process.
NOTE: END-OF-THE-LINE test can be performed with the LITE-CHECK tablet.
·
Press ABS on the tablet keypad.
·
Press the SELECT once to charge the emergency line.
·
Press the SELECT a second time to charge the service line.
·
Spin wheel to the required speed and press BRAKE to apply service air.
·
Wheel should stop if ABS is connected properly.
·
Repeat wheel spin for wheels under ABS control.
7. Close the ABS program on the PC.
Lite-Check CERTIFIER 1200 Operations Manual
23
PERFORMING ABS TESTS