URRACO 75 D
S
ERVICE GUIDELINES
Managing director
LINDNER
Mobile Shredder GmbH
Industriestrasse 1A
D-99820 Hörselberg / Eisenach
Service hotline:
+49 (0) 36920 - 7269 - 600
Manuel Lindner
Gerhard Buhl
Walter Geiger
Page - 9 - of - 38 -
Hydraulic
oil
approx. 120 litres Hydraulic oil according to DIN 51524
part 2, select the viscosity class from the
diagram according to the climatic
conditions
Purity class
18/13 according to ISO 4406 or better.
Factory-filled:
HLP 46
every 500 to 1000
hours
or twice yearly
(depending on
contamination level)
Auswahldiagramm
Selection diagram
A = arktische Verhältnisse oder für extrem lange Leitungen
A = arctic conditions or for extremely long lines
W = winterliche Verhältnisse in Mitteleuropa
W = winterly conditions in Middle Europe
S = sommerliche Verhältnisse in Mitteleuropa oder geschlossene
Räume
S = summerly conditions in Middle Europe
T =tropische Verhältnisse oder Räume mit starkem Wärmeanfall
T =tropical conditions or rooms with high heat exposure
U = übermäßig starker Wärmeanfall (z.B. durch
Verbrennungsmaschinen)
U =excessively high heat exposure (e.g., by combustion engines)
Max. zul. Viskosität (kurzzeitig)
max. permissible viscosity (short-term)
Optimaler Betriebsviskositätsbereich optimaler Wirkungsgrad
Optimal operating viscosity range, optimal efficiency
min. zul.. Viskosität (kurzzeitig)
min. permissible viscosity (short-term)
min. zul. Viskosität (kurzzeitig)
min. permissible viscosity (short-term)
Temperatur t in °C
Temperature t in °C
1) Druckflüssigkeitstemperaturbereich
1) Pressure liquid temperature range
Produkt- bzw. nenngrößenabhängig gelten folgende
Viskositätsbereiche:
The following viscosity ranges apply, depending on product or
nominal size:
(Der max. zul. Viskositätsbereich ist den Katalogblättern der
einzelnen Produkte zu entnehmen)
(For the maximum admissible viscosity range, refer to the
catalogue sheets of every product.)