User Manual
Operating Instructions
2.1EN-38016-C09
Maintenance and Repair
Electrical Connection
WARNING!
Before maintenance or repair of pumps
switch off their power supply.
Consider the safety instructions (page 5
and 6)!
4273a 00
CAUTION!
Before starting, make sur e that the general
power supply is off. The device must never
be connected or disconnected when the
power is on. The protective conductor must
always be c onnec ted. Take care that this
line section is undamaged and conform s to
standards and the contacts are safe.
6001a 02
NOTE
The protection IP6K9K is guaranteed when
the socket ( X1:, X2: & X3:) is tightened on
the housing cover with flat packing.
NOTE
Consider the contact protection measures
for c onnecting the high- or low-level control
(see chapter “Mode of Operation” / para-
graph „Low- or High-level Control”).
Make s ure of the connection and the type of construc tion
of your QLS 401.
- type of connection (VDC / VAC)
- low-level indication
- type of connection plug
- monitoring of metering device via external or internal
cycle switc h
Connect the electrical wires according to the following
electrical connecting diagrams (see chapter „Technical
Data“).
Maintenance, Repair and Tests, continuation
4273a 00
ATTE NTION!
Control p.c.b. and motor always work with
24 VDC even if the pump is connected to
alter nating current.
Consider residual ripple of max.
5 %
when connecting motor and control p.c .b.
(in relation to the operating voltage acc. to
DIN 41755).
Operation with bayonet plug
4273a 00
CAUTION!
If the protective-conductor terminal is not
connected or interrupted, dangerous touch
voltages may occur on the equipment!
Protective measures to be applied for appropriate operation
with bayonet plugs :
"Functional extra-low voltage with safe is olation" /
"Protective Extra-Low Voltage" (PELV)
Standards :
EN60204 Part1:1992 / IEC 204-1:1992, modified
DIN VDE 0100 Part 410 / IEC 364-4-41:1992