User Manual
Operating Instructions
2.1EN-38016-C09
Return Line Connection
Fig. 6-1 Return Line Connection
T-P203Fp-020e08
The lubricant quantities which cannot be dispens ed by the
metering device must be returned to the pump via the re-
turn line connection.
Low Level Control
Fig. 8-1 Switching parts of the low-level control
(reservoir filled)
B-P203M-030a08
1 -
Guiding plate with rou nd
solenoid
2 -
Electromagnetic switch
3 -
Control cam
A - Inner orbit of the round sole-
noid
B -
Position of the guidin g plate
(entered)
Reservoir filled
The stirring paddle rotates
clockwise
during the lubricating
tim e.
The entry of the stirring paddle B (fig. 8-1) into the lubricant
presses the pivoted guiding plate with the round solenoid 1
inwards to orbit A.
The solenoid switch 2
cannot
be activated contact-free.
Control cam 3 guides the round solenoid with the pivoting
guiding plate automatically outwards, in the direction of the
reservoir wall. When leav ing the control cam, the lubricant
presses against the guiding plate and moves the solenoid
inwards again (B).
6001a02
NOTE
The switch parts of the low-level control
(items 1 to 3) cannot be used with fluid
greases.
Mode of Operation, continuation
Fig. 8-2 Switching parts of the low-level control
(reservoir empty)
B-P203M-030b08
1 -
Guiding plate with round
solen oid
2 -
Electromagnetic switch
3 -
Control cam
C -
Outside orbit of the round
solenoid
B -
Position of the guiding plate
(unentered)
When the reservoir is empty
6 001a02
NOTE
The flashing signal * LL * starts as soon as
the solenoid has activated the solenoid
switch six times contact-free.
When passing the control cam 3 (fig. 8-2) the solenoid
remains in the outer orbit C and thereby passes the sole-
noid switch 2. The solenoid activ ates the solenoid switch
contact-free and so initiates a low-level indication.
When the stirring paddle rotates on the outer orbit C there
is no counterpressure by lubricant.
The guiding plate with the round solenoid 1 remains un-
entered (D).