User Manual
Operating Instructions
2.1EN-38016-C09
Installation position of the printed circuit boards
PCB 1
Control and power supply board inside the
h ousing
6 344b04
The
printed circuit board
1 (for VDC & VAC pumps) and
the
power supply board
2 (only for VAC pumps) are in-
tegrated in the pump housing.
6001a02
IMPORTANT
Whenever the pump housing has been
opened (e. g. for replacing of the p.c.b.), the
housing cover (including the foamed seal)
must be replaced.
1
- control printed circuit board
(input VDC)
2
- power supply board
(input VAC, output VDC)
Mode of Operation
20002 443b-1
PCB 2
Printed circuit board 236-13891-1
The printed circuit board automatically controls the se-
quence of the pause and lubricating times of the
central
lubrication pump
.
The sequence of the pause and lubricating times is acti-
vated when the power supply is switched on:
- via machine contact … ……….… for VDC or VAC pumps
……………………………………….. industrial application
- via driving switch …………………… only for VDC pumps
………………………………………….. mobile applicaiton
Printed Circuit Board V10-V13
1)
(V20-V23)
1)