SMAL CANlift
MAN SMAL I6 E 1.3.doc
Pag.19
www.lika.it
www.lika.biz
6.8.3 Device profile objects (DSP 417)
NOTE:
In order to simplify the use and to avoid gaps of DSP417 profile, LIKA devices
don’t support the dynamic allocation of objects based on the lift number
parameter.
Index and sub;index value are fix values and referred to:
“lift number” = 1, “car position unit” = 1.
This setting doesn’t generate errors because the COB;ID of SDO depends on the
Node;ID (see object 3001;00).
600100
Lift number [Unsigned8, rw]
This object contains the number of the lift to which this device is assigned.
Possible value are:
Data byte
Description
01h
(default) lift 1
02h
lift 2
04h
lift 3
08h
lift 4
10h
lift 5
20h
lift 6
40h
lift 7
80h
lift 8
The correct procedure to change lift number is:
•
set object 6001h
•
send a “reset node”
•
store parameter.
Default = 01h
Master
Slave
COBID
Cmd
Index
Sub
Data byte
600+ID
2F
01
60
00
new lift
Slave
Master (confirmation)
COBID
Cmd
Index
Sub
Data byte
580+ID
60
01
60
00
00
Master
Slave (reset node)
COBID
Cmd
Slave ID
000
81
Node;ID
Slave
Master (Boot;up)
COBID
Cmd
700+ID
00
NOTE:
Store parameters (see object 1010h) to save the new Node;ID value.