SMAL CANlift
MAN SMAL I6 E 1.3.doc
Pag.22
www.lika.it
www.lika.biz
6.9 Warning objects
In order to know the meaning of warning message make reference to the
document “CiA Draft Standard 301” on chapter “SDO abort codes” available on
www.can;cia.org.
6.10 Emergency objects
Emergency (EMCY) objects are transmitted by the device when an internal error
occurs.
EMCY structure:
IDENTIFIER
CAN Data Byte
COB;ID(hex)
0
1
2
3…7
see object 1014h
Error code
Sub of error
register
Specific code
LSB
MSB
01
00…00
Defined error codes:
1000h = Node guarding error
5530h = Flash memory error
6.11 Node guarding protocol
On start up the “Node guarding protocol” is disabled, the Master device can
enable the protocol by sending an RTR (remote transmit request).
Guard time: time between 2 RTR.
Node life time: max device response time.
“Node life time” = “Obj_100C”
∗
“Obj_100D”
“Node guarding” is enabled if “Node life time”
≠
0.
If the Slave is not guarded within the "Node life time", it warns with a “Life
Guarding Event”.
The red LED indicates the Node guarding error, objects 1001h and 1003h are
updated and error message is sent.
To remove the error send a “Reset node” command.
time
Master
Slave
RTR
request
NodeGuard.
response
RTR
request
Node
life
time
Node guarding
event
Life guarding
event
Guard
time