SMAL CANlift
MAN SMAL I6 E 1.3.doc
Pag.14
www.lika.it
www.lika.biz
100800
Manufacturer device name [String, ro]
Contains the name of device manufacturer.
Default = “Lika”
100900
Hardware version [String, ro]
Contains the hardware version of device.
100A00
Software version [String, ro]
Contains the software version of device.
100C00
Guard time [Unsigned16, rw]
Contains the Guard time expressed in msec (milliseconds)
Default = 03E8h
100D00
Life time factor [Unsigned8, rw]
Default = 05h
“Guard time” and “Life time factor” objects are used in “Node guarding protocol”
controlled by Master. For more details see chapter 6.11.
101001
Store parameters [Unsigned32, rw]
Use this object to save all parameters in non;volatile memory.
Write "save" in the data bytes:
Master
Slave
COBID
Cmd
Index
Sub
Data bytes
600+ID
23
10
10
01
73
61
76
65
Slave
Master (confirmation)
COBID
Cmd
Index
Sub
Data bytes
580+ID
60
10
10
01
00
00
00
00