SMAL CANlift
MAN SMAL I6 E 1.3.doc
Pag.6
www.lika.it
www.lika.biz
5 Electrical connections
ATTENTION:
minimize noise by connecting shield or device body to ground (GND). Make sure
that ground (GND) is not affected by noise. It’s recommended to provide the
ground connection as close as possible to the device.
M12
Colour
Description
2
Red
+10Vdc +30Vdc
Supply voltage
3
Black
0 Vdc
Supply voltage
4
White
CAN_H
5
Blue
CAN_L
1
Shield
CAN_Shield
M12 connector:
male, frontal side
5.1 LED indicator
Three LEDs show the status of the CAN interface following the table below:
GREEN LED 1
Description
ON
Power supply ON
OFF
Power supply OFF
RED LED 2
Description
ON
Bus off
Double flash
Node guarding error
Single flash
Warning limit reached
Blinking
Generic error or flash memory error
OFF
No error
GREEN LED 3
Description
ON
The encoder is in state Operational
Single flash
The encoder is in state Stopped
Blinking
The encoder is in state Pre;Operational
During device initialization an hardware test is made to check if LEDs work
correctly.
L1 L2 L3