SMAL CANlift
MAN SMAL I6 E 1.3.doc
Pag.5
www.lika.it
www.lika.biz
4 Quick reference
The device position can be read using default parameters.
Follow the steps below:
1
set “event timer”;
2
set “operational” mode;
3
read position (cyclic mode).
Step 1 is necessary only at first time the device is used.
If parameters are stored (“Store parameters” function, see object 1010h) the
event timer will be already set at the next power on of the device.
Main default values are:
Baud rate = 500 Kbit/s
Node;ID = 1
Lift number = 1
Car position unit = 1
Set “event timer” (100ms = 64h)
Master
SMAL
COBID
Cmd
Index
Sub
Process data
601
2B
06
19
05
64
00
;
;
SMAL
Master
COBID
Cmd
Index
Sub
Process data
581
60
06
19
05
00
00
00
00
Store parameters (see object 1010h) to save the new value.
Set Operational mode
Master
SMAL
COBID
Cmd NodeID
000
01
01
Read position every 100ms
SMAL
Master
COBID
Byte 0
Byte 1
Byte 2
Byte 3
18C
Low
…
…
High