![Lightware HDMI20-OPTC-RX220-Pro Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/lightware/hdmi20-optc-rx220-pro/hdmi20-optc-rx220-pro_user-manual_1915378055.webp)
6. LW3 Programmers’ Reference
HDMI20-OPTC series – User's Manual
55
EDID Management
Operation / Path
/EDID.EdidStatus
Querying the Validity of a Dynamic EDID
/EDID/D/D1.Validity
Querying the Preferred Resolution of an User EDID
/EDID/U/U1.PreferredResolution
Emulating an EDID to an Input Port
/EDID:switch(<source>:<destination>)
Copying an EDID to User Memory
/EDID:copy(<source>:<destination>)
Deleting an EDID from User Memory
/EDID:delete(<user_edid_memory>)
/EDID:reset(1)
RS-232 Port Configuration
Operation / Path
Querying the RS-232 Opearation Mode
/MEDIA/UART/P1.Rs232Mode
Setting the RS-232 Opearation Mode
/MEDIA/UART/P1.Rs232Mode
/MEDIA/UART/P1.Baudrate
/MANAGEMENT/NETWORK.StaticNetworkMask
/MEDIA/UART/P1.StopBits
/MEDIA/UART/P1.Parity
Enabling Command Injection Mode
/MEDIA/UART/P1.CommandInjectionEnable
Sending Message via the Communication Ports
Operation / Path
Sending Message via an RS-232 Port
/MEDIA/UART/P1:sendMessage(<message>)
/MEDIA/UART/P1:sendText(<text>)
/MEDIA/UART/P1:sendBinaryMessage(<binarymessage>)
/MEDIA/ETHERNET:tcpMessage(<IP_address>:<port_no>=<message>)
/MEDIA/ETHERNET:tcpText(<IP_address>:<port_no>=<message>)
/MEDIA/ETHERNET:tcpBinary(<IP_address>:<port_no>=<message>)
/MEDIA/ETHERNET:udpMessage(<IP_address>:<port_no>=<message>)
/MEDIA/ETHERNET:udpText(<IP_address>:<port_no>=<message>)
/MEDIA/ETHERNET:udpBinary(<IP_address>:<port_no>=<message>)