5. Software Control - Lightware Device Controller
UMX-HDMI-140 series– User's Manual
57
Applied firmware package: v1.2.0 | LDC software: v2.4.1b7
5.13.
Advanced View Window
1
2
3
4
5
6
7
1
LW3 protocol help
Pushing the button results a help window opening which describes the most
important information about LW3 protocol commands in HTML format.
2
Edit mode
The default appearance is the read-only mode. If you want to modify the
values or parameters, tick the option. You will be prompted to confirm your
selection.
3
Warning mode
If this pipe checked in, a warning window pops up when you enable Edit mode.
4
Terminal window
Commands and responses with time and date are listed in this window. Sent
command starts with ‘>’ character, received response starts with ‘<’ character.
The color of each item depends on the type of the command and response.
The content of the window can be emptied by the
Clear
button. If the
Autoscroll
option is ticked, the list is scrolled automatically when a new line is added.
5
Command line
Type the desired command and execute it by the
Send
button. Clear all current
commands and responses in the Terminal window by the
Clear
button.
6
Protocol tree
LW3 protocol tree; select an item to see its content.
7
Node list
Correspondent parameters and nodes are shown which are connected to the
selected item in the protocol tree.
Manual
button: Manual (short description) of the node can be called and
displayed in the terminal window.
Set
button:
Saves the value/parameter typed in the textbox.
Call
button:
Calls the method, e.g. reloads factory default settings.
#terminal #advancedview