5. Software Control - Lightware Device Controller
UMX-HDMI-140 series– User's Manual
48
Applied firmware package: v1.2.0 | LDC software: v2.4.1b7
Ports Tab in UMX-HDMI-140-Plus
Infra tab - Ports Window - UMX-HDMI-140-Plus
The user can set the name and command injection port to each sources and destinations. For more details
about IR interface see the
The following settings are also available:
▪
Port name;
▪
Enable / disable the port;
▪
Port number;
▪
Enable / disable command injection;
▪
Message sending function (little-endian prontohex code) For more details see the
section;
▪
Reload
Sending pronto hex codes (Little-endian format)
Copy the raw, little endian-format IR code into the
Send Pronto Hex
entry field and click the
Send
button.
The maximum length of the code can be 765 characters (765 bytes). For more details about the accepted IR
code formats, see
Sending Pronto Hex Codes in Little-endian Format via IR Port
This entry field does not store the code. The code can be saved into the action in the event manager with
the following parameters:
Category:
Infra;
Expression:
Send pronto hex
; Port:
D1;
Pronto hex:
<custom_code>
In the Event Manager, the maximum length of the code can be 184 characters (184 bytes).
INFO:
Sending bigger endian-format code is available with LW3 protocol command, see
Hex Codes in Big-endian Format via IR Port
Ports Tab in UMX-HDMI-140
User can set the name and command injection port to each sources and destinations. For more details
about IR interface see the
section.
Infra tab - Ports Window - UMX-HDMI-140
Clear all IR codes
Clicking on the button results deleting all stored IR fingerprints.