Common Problems and Solutions
• Unit may not be plugged
in correctly.
• Unit may be plugged into
an outlet controlled by a
switch.
• Fuse at the bottom of the
machine may be blown.
• Make sure power plug is
plugged into outlet
correctly.
• Plug unit into an outlet that
is constantly ‘hot’.
• Replace the fuse at the bottom
of the unit.
• The power
light is not
on or the
power switch
doesn’t seem
to work.
• Angle Valve Adapter
and/or cold water
supply are turned off.
• One or more of the water
supply tubes is crimped.
• House water pressure is
too low.
•Pre-filter and/or unit
filters are blocked.
• Water
volume is low
or doesn’t
come out of
the unit.
• Make sure all water supply
valves are open.
• Check all hoses and tubes.
• Water pressure may be low
for many reasons
(RO system, sprinkler
system, etc)
Call LIFE Ionizer
TM
Tech
Support for assistance.
• If unit has been used for
6 months or more, replace
filters as needed.
• Tubing to pre-filter is
not seated deeply
enough.
• O-Rings inside the
pre-filter are not seated
correctly or are being
crimped due to housing
cover being on too tight.
• Disconnect and reseat
tubing at least 3/4 inches into
filter.
• Disconnect tubing and
unscrew housing cover. Make
sure O-Rings are seated
properly.
• Pre-filter is
leaking.
• Tube is not seated
properly or there is a
hole in the tubing.
• Tubing is
leaking.
• Disconnect and reconnect
tubing making sure it is
seated 3/4 inch deep or
replace tubing.