Lifasa MASTER control Var Скачать руководство пользователя страница 6

 REVISION LOG

Table 1: Revision log�

Date

Revision

Description

07/18

M021B02-03-18A

Initial Version

6

Controller MASTER control VAR FAST

Instruction Manual

Содержание MASTER control Var

Страница 1: ...INSTRUCTION MANUAL M021B02 03 18A REACTIVE ENERGY REGULATOR Controller MASTER control VAR FAST Static operation ...

Страница 2: ...2 Controller MASTER control VAR FAST Instruction Manual ...

Страница 3: ...d be taken into consideration Incorrect handling or installation of the unit may result in injury to personnel as well as damage to the unit In particular handling with voltages applied may result in electric shock which may cause death or serious injury to personnel Defective installation or maintenance may also lead to the risk of fire Read the manual carefully prior to connecting the unit Follo...

Страница 4: ...E UNIT 21 4 OPERATION 22 4 1 DEFINITIONS 23 4 1 1 FOUR QUADRANT REGULATOR 23 4 1 2 STAGES AND STEPS 23 4 1 3 FCP SYSTEM FAST Computerized Program 23 4 1 4 REGULATION PROGRAM 23 4 1 5 PLUG AND PLAY 24 4 1 6 CONNECTION TIME Ton AND RECONNECTION TIME Trec 24 4 1 7 THD AND HARMONICS 24 4 2 MEASUREMENT PARAMETERS 25 4 2 1 CONNECTION TYPE 3U 3C 25 4 2 2 CONNECTION TYPE 3U 1C 26 4 2 3 CONNECTION TYPE 2U ...

Страница 5: ...LOGUE BAR 88 5 15 FAN 89 5 16 RS 485 COMMUNICATIONS 90 5 17 CPC NET COMMUNICATIONS 91 5 18 CLEAR 92 5 19 ENABLING ALARMS 93 5 20 VOLTAGE ALARMS 94 5 21 COS φ ALARM 95 5 22 VOLTAGE THD ALARM 96 5 23 CURRENT x I THD ALARM 97 5 24 TEMPERATURE ALARM 98 5 25 LEAKAGE CURRENT ALARM 100 5 26 NO OF OPERATIONS ALARM 101 5 27 SIMULATION SCREEN 102 6 TECHNICAL FEATURES 103 7 MAINTENANCE AND TECHNICAL SERVICE ...

Страница 6: ...REVISION LOG Table 1 Revision log Date Revision Description 07 18 M021B02 03 18A Initial Version 6 Controller MASTER control VAR FAST Instruction Manual ...

Страница 7: ... the type of grid to which the unit will be connected Voltage and power supply fre quency measurement range etc d Perform an external visual inspection of the unit prior to switching it on e Check that it has been delivered with the following An installation guide Four retainers for rear attachment of the unit If any problems are detected upon reception immediately contact the trans port company a...

Страница 8: ...ontroller MASTER control VAR FAST 12 with twelve optoMOS relay outputs The unit features 5 keys that can be used to browse the various screens and program the unit 4 indicator LEDs CPU ALARM FAN and KEY PRESSED LCD display amber backlit 70x60 7 mm display for viewing all the parameters 2 digital inputs for selecting the target cosine 4 target cosines 2 digital outputs and 1 relay output fully prog...

Страница 9: ...avoid accidents personal injury and damage to installations The manufacturer of the unit is not responsible for any damage resulting from failure by the user or installer to heed the warnings and or recommendations that appear in this manual nor for damage resulting from the use of products or accessories that did not come with the unit or that were made by other manufacturers If an anomaly or mal...

Страница 10: ...ompliance with DIN 43700 All connections are inside the electric panel Terminals opening roofs or removing elements can expose parts that are haz ardous to the touch while the unit is powered Do not use the unit until it is fully installed The unit must be connected to a power circuit that is protected with gl IEC 269 or M type fuses with a rating of 0 5 to 2 A It must be fitted with a circuit bre...

Страница 11: ... r e c o n n e c t e d in this position NONE OF THE CAPACITORS WILL BE CONNECTED even if there are inductive loads The unit does not compensate LOAD CAPACITORS P1 P2 S1 S2 TC If the CTs are connected in this position ALL THE CAPACITORS WILL BE CONNECTED but they will not be disconnected if the load drops Risk of over compensation in the grid with no load Figure 1 Location of the current transforme...

Страница 12: ...nt input 31 1 Digital input 1 10 S2 L2 current input 32 2 Digital input 2 11 S1 L3 current input 33 C Digital inputs common 12 S2 L3 current input 34 1 Digital output 1 13 S1 Leakage current input 35 2 Digital output 2 14 S2 Leakage current input 36 C Digital outputs common 15 COM Outputs common 37 Fan relay output 16 1 Output 1 38 Fan relay output 17 2 Output 2 39 NC Alarm relay output 18 3 Outpu...

Страница 13: ...9 10 11 12 13 15 14 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 Figure 2 Controller MASTER control VAR FAST terminals 13 Instruction Manual Controller MASTER control VAR FAST ...

Страница 14: ...r Supply COM 1 2 3 4 5 6 COM ACT C1 C6 Power Supply Figure 3 3 voltages Neutral and 3 currents Controller MASTER control VAR FAST 6 model Note If the connection layout mentioned above is not respected you must adjust the phase following the procedure described in section 5 6 PHASE CONNECTION Note In this type of connection the connection from Neutral to VLN is not mandatory 14 Controller MASTER co...

Страница 15: ... 11 12 COM ACT C1 C12 Power Supply Power Supply Figure 4 3 voltages Neutral and 3 currents Controller MASTER control VAR FAST 12 model Note If the connection layout mentioned above is not respected you must adjust the phase following the procedure described in section 5 6 PHASE CONNECTION Note In this type of connection the connection from Neutral to VLN is not mandatory 15 Instruction Manual Cont...

Страница 16: ...Neutral and 1 current Controller MASTER control VAR FAST 6 model Note If the connection layout mentioned above is not respected you must adjust the phase following the procedure described in section 5 6 PHASE CONNECTION Note In this type of connection the connection from Neutral to VLN is not mandatory Note In this type of connection the current transformer must be connected to the IL1 termi nals ...

Страница 17: ...oltages Neutral and 1 current Controller MASTER control VAR FAST 12 model Note If the connection layout mentioned above is not respected you must adjust the phase following the procedure described in section 5 6 PHASE CONNECTION Note In this type of connection the connection from Neutral to VLN is not mandatory Note In this type of connection the current transformer must be connected to the IL1 te...

Страница 18: ...ler MASTER control VAR FAST 6 model Note If the connection layout mentioned above is not respected you must adjust the phase following the procedure described in section 5 6 PHASE CONNECTION Note In this type of connection the Neutral connection is not necessary Note In this type of connection the current transformer must be connected to the IL1 termi nals and the two voltages must be connected to...

Страница 19: ... Controller MASTER control VAR FAST 12 model Note If the connection layout mentioned above is not respected you must adjust the phase following the procedure described in section 5 6 PHASE CONNECTION Note In this type of connection the Neutral connection is not necessary Note In this type of connection the current transformer must be connected to the IL1 termi nals and the two voltages must be con...

Страница 20: ...ank TC LOAD CAPACITORS S1 S2 P1 P2 I S1 S1 S2 S2 IL1 IL2 IL3 Figure 9 Connection of the leakage current transformer IΔ Note The earth leakage transformer must have a ratio of 500 turns The maximum leakage current that the unit can measure correctly is 1 5A AC even though the maximum input is 5A AC via the earth leakage transformer Do not operate the leakage current transformer with the Controller ...

Страница 21: ... the following screen appears on the display Figure 10 which shows the name of the unit the version and the model Figure 10 Controller MASTER control VAR FAST home screen After a few seconds the main measurement screen appears 21 Instruction Manual Controller MASTER control VAR FAST ...

Страница 22: ...ller MASTER control VAR FAST Performs the functions of a network analyzer measuring and displaying multiple parameters Has a Plug Play function for automatic configuration of the unit Has an AutoTest and manual Test function for testing the status of the capacitor bank capac itors Has an FCP system which minimises the number of capacitor connections and disconnec tions Supports step forcing Can wo...

Страница 23: ...ve a pre determined required final power The operations are carried out such that in the case of stages with identical power the stage that has been disconnected the longest is connected when there is demand and the stage that has been connected the longest is disconnected when there is a surplus 4 1 4 REGULATION PROGRAM The power ratings of the various groups or stages usually follow certain patt...

Страница 24: ...ion time Ton defines the shortest possible time between changes in the status of the stages in other words between connections and disconnections Therefore the configu ration of this parameter has a direct impact on the compensation speed in other words on the capacity for monitoring load changes Setting a shorter connection time improves the power factor correction when the load can change quickl...

Страница 25: ...ter Units Phases L1 L2 L3 N Total III Max 1 Min 2 Phase neutral voltage V Phase phase voltage V Current A Leakage current mA Frequency Hz L1 Active Power M kW Apparent Power M kVA Total Reactive Power M kvar Inductive Reactive Power M kvarL Capacitive Reactive Power M kvarC Power factor PF Cos φ φ Voltage THD THD V Current THD THD A Harmonic Breakdown Voltage up to the 17th harmonic harm V Harmoni...

Страница 26: ...ctive Reactive Power M kvarL Capacitive Reactive Power M kvarC Power factor PF Cos φ φ Voltage THD THD V Current THD THD A L1 Harmonic Breakdown Voltage up to the 17th harmonic harm V Harmonic Breakdown Current up to the 17th harmonic harm A L1 Active energy M kWh Inductive Reactive Energy M kvarLh Capacitive Reactive Energy M kvarCh Apparent energy M kVAh Temperature ºC No of operations x1000 Tot...

Страница 27: ...ve Reactive Power M kvarL Capacitive Reactive Power M kvarC Power factor PF Cos φ φ Voltage THD THD V L1 L2 Current THD THD A L1 Harmonic Breakdown Voltage up to the 17th harmonic harm V L1 L2 Harmonic Breakdown Current up to the 17th harmonic harm A L1 Active energy M kWh Inductive Reactive Energy M kvarLh Capacitive Reactive Energy M kvarCh Apparent energy M kVAh Temperature ºC No of operations ...

Страница 28: ... the Test screens Note See 4 6 1 MEASUREMENT STATUS for further details Key functions on the Configuration and Test screens query mode Table 7 Table 7 Key functions on the Configuration and Test screens query mode Key Short press Long press 3 s Previous screen Test Manual connection of the selected capacitor Next screen Test Manual disconnection of the selected capacitor Previous parameter Next pa...

Страница 29: ...t screens edit mode Key Short press Increase the value or show the next option Reduce the value or show the previous option Next configuration parameter Previous configuration parameter Exit Edit mode Note See 4 6 2 TEST STATUS and 5 CONFIGURATION for further details 29 Instruction Manual Controller MASTER control VAR FAST ...

Страница 30: ... The data area displays the instantaneous maximum and minimum values of each one of the phases which the unit is measuring or calculating Status of the capacitors displays the status of the unit s relays Status of the unit displays the current status of the unit Analogue bar configurable shows the current current THD or connected power of the capacitor bank as a percentage 30 Controller MASTER con...

Страница 31: ...age cur rent alarm E15 In the setup menu 5 12 STATUS OF THE STAGES the status of the stages is selected from the following options AUTO The status of the stage depends on the operation performed by the unit On Stage forced to ON always connected OFF Stage forced to OFF always disconnected On NC Stage forced to ON always connected but the system does not take into account its connected power By def...

Страница 32: ...tors 4 4 4 OTHER SYMBOLS ON THE DISPLAY The display also shows the following Alarm When the unit detects an alarm the backlight of the display flashes and the alarm icon lights up The cause of the alarm can be seen on the active alarms screen 4 6 OPERATING STATES Target cosine The icons indicate which one of the 4 possible target cosines has been selected 5 3 TARGET COS φ Editing locked unlocked T...

Страница 33: ...linking once per second An Alarm LED Indicates that an alarm is activated A Fan LED Indicates that the fan is operating A key pressed LED Lights up when any of the 5 keys are pressed CPU Fan Alarm Key pressed Figure 15 LED indicators of the Controller MASTER control VAR FAST 33 Instruction Manual Controller MASTER control VAR FAST ...

Страница 34: ...he various screens Delete maximum values On the maximum value display screen press the key for more than 3 seconds Delete minimum values On the minimum value display screen press the key for more than 3 seconds If 5 minutes pass without any keys being pressed the unit returns to the main screen The display screens vary according to the connection type of the installation 4 6 1 1 3U 3C Connection 3...

Страница 35: ...e Voltages Parameters L1 Phase Phase Voltage V or kV L2 Phase Phase Voltage V or kV L3 Phase Phase Voltage V or kV Phase Phase Voltage III V or kV Display the minimum values Display the maximum values Currents Parameters L1 Current A L2 Current A L3 Current A N Current A Display the minimum values Display the maximum values Press the or key to switch to the Cosine φ screen 35 Instruction Manual Co...

Страница 36: ...L1 Power Factor L2 Power Factor L3 Power Factor Power Factor III L Inductive C capacitive Consumed generated Display the minimum values Display the maximum values Power III Parameters Active Power III kW or MW Inductive Reactive Power III kvarL or MvarL Capacitive Reactive Power III kvarC or MvarC Apparent Power III kVA or MVA Display the minimum values Display the maximum values 36 Controller MAS...

Страница 37: ...Power L2 Inductive Reactive Power L3 Inductive Reactive Power Inductive Reactive Power III kvarL or MvarL Display the minimum values Display the maximum values Capacitive Reactive Power Parameters L1 Capacitive Reactive Power L2 Capacitive Reactive Power L3 Capacitive Reactive Power Capacitive Reactive Power III kvarC or MvarC Display the minimum values Display the maximum values 37 Instruction Ma...

Страница 38: ...lues Display the maximum values Leakage current Frequency Temperature Parameters Leakage current mA Frequency Hz Temperature ºC Display the minimum values Display the maximum values Voltage THD Parameters L1 Voltage THD L2 Voltage THD L3 Voltage THD Display the maximum values 38 Controller MASTER control VAR FAST Instruction Manual ...

Страница 39: ...splay the maximum values Current THD Parameters L1 Current THD L2 Current THD L3 Current THD Display the maximum values Current harmonics Parameters L1 Current harmonic L2 Current harmonic L3 Current harmonic Change the harmonic no 3 5 7 9 11 13 15 17 Display the maximum values 39 Instruction Manual Controller MASTER control VAR FAST ...

Страница 40: ...rated kvarCh or MvarCh Apparent Energy III generated kVAh or MVAh Operations Parameters No of operations of stage C1 to C12 Three screens show the number of operations of the 12 possible stages for more than 3 seconds delete the no of operations This parameter should be associated with an alarm that is activated when the number of oper ations exceeds a pre determined value for example 5000 operati...

Страница 41: ...alse actions this alarm has a predefined delay of 90 seconds E04 Overcurrent The measured current exceeds the nominal current by 20 in some of the phases The nominal current is considered to be that of the CT primary In order to avoid possible false actions this alarm has a predefined delay of 5 seconds E05 Overvoltage The voltage measured in some of the phases exceeds the con figured voltage Vp n...

Страница 42: ...e displayed In order to enable these capacitors again view the configuration of the Leakage alarm E16 Leakage transformer detection Alarm The Leakage alarm has been enabled but the unit does not detect the connection of the leakage current transformer E17 Number of connections alarm The configured number of operations has been exceeded any capacitor In these alarms two levels have been configured ...

Страница 43: ...itch to the Currents screen Phase Neutral Voltages Parameters L1 Phase Neutral Voltage V or kV L2 Phase Neutral Voltage V or kV L3 Phase Neutral Voltage V or kV Phase Neutral Voltage III V or kV Display the minimum values Display the maximum values Phase Phase Voltages Parameters L1 Phase Phase Voltage V or kV L2 Phase Phase Voltage V or kV L3 Phase Phase Voltage V or kV Phase Phase Voltage III V ...

Страница 44: ... Cos φ L Inductive C capacitive consumed generated Display the minimum values Display the maximum values Press the key to switch to the Energy III consumed screen Power Factor Parameters Power factor L Inductive C capacitive consumed generated Display the minimum values Display the maximum values 44 Controller MASTER control VAR FAST Instruction Manual ...

Страница 45: ...r MVA Display the minimum values Display the maximum values Leakage current Frequency Temperature Parameters Leakage current mA Frequency Hz Temperature ºC Display the minimum values Display the maximum values Voltage THD Parameters L1 Voltage THD L2 Voltage THD L3 Voltage THD Display the maximum values 45 Instruction Manual Controller MASTER control VAR FAST ...

Страница 46: ...the harmonic no 3 5 7 9 11 13 15 17 Display the maximum values Current THD Parameters Current THD Display the maximum values Current harmonics Parameters Current harmonic Change the harmonic no 3 5 7 9 11 13 15 17 Display the maximum values 46 Controller MASTER control VAR FAST Instruction Manual ...

Страница 47: ...rated kvarCh or MvarCh Apparent Energy III generated kVAh or MVAh Operations Parameters No of operations of stage C1 to C12 Three screens show the number of operations of the 12 possible stages for more than 3 seconds delete the no of operations This parameter should be associated with an alarm that is activated when the number of oper ations exceeds a pre determined value for example 5000 operati...

Страница 48: ...Active alarms Parameters Active alarm code E01 to E017 Table 9 If there are more than 4 alarms the information is scrolled on the screen 48 Controller MASTER control VAR FAST Instruction Manual ...

Страница 49: ...tage V or kV Display the minimum values Display the maximum values Press the key to switch to the Currents screen Phase Phase Voltages Parameters Phase Phase Voltage V or kV Display the minimum values Display the maximum values Currents Parameters Current A Display the minimum values Display the maximum values Press the or key to switch to the Cosine φ screen 49 Instruction Manual Controller MASTE...

Страница 50: ...arameters Power factor L Inductive C capacitive consumed generated Display the minimum values Display the maximum values Power III Parameters Active Power III kW or MW Inductive Reactive Power III kvarL or MvarL Capacitive Reactive Power III kvarC or MvarC Apparent Power III kVA or MVA Display the minimum values Display the maximum values 50 Controller MASTER control VAR FAST Instruction Manual ...

Страница 51: ...e ºC Display the minimum values Display the maximum values Voltage THD Parameters Voltage THD Display the maximum values Voltage harmonics Parameters Voltage harmonic Change the harmonic no 3 5 7 9 11 13 15 17 Display the maximum values 51 Instruction Manual Controller MASTER control VAR FAST ...

Страница 52: ... Display the maximum values Energy III consumed Parameters Active Energy III consumed kWh or MWh Inductive Reactive Energy III consumed kvarLh or MvarLh Capacitive Reactive Energy III consumed kvarCh or MvarCh Apparent Energy III consumed kVAh or MVAh Press the key to switch to the Main screen 52 Controller MASTER control VAR FAST Instruction Manual ...

Страница 53: ... than 3 seconds delete the no of operations This parameter should be associated with an alarm that is activated when the number of oper ations exceeds a pre determined value for example 5000 operations in order to perform the maintenance of this stage There are thousands of operations so the value displayed is in thousands of operations which is the reason for the k icon Active alarms Parameters A...

Страница 54: ...est screens causes the unit to return to the Measurement status Use keys and to browse the various screens If 5 minutes pass without any keys being pressed the unit returns to the main screen Disconnection screen Parameters Transition screen used for the unit to disconnect all the stages automatically before entering Test status While in this screen the unit does not respond to the keys The unit a...

Страница 55: ...ns to the Individual Test screen Individual Test Parameters Leakage current mA Capacitive Reactive Power kvarC or MvarC Capacitive Power of each capacitor relative to the total estimated value Switches between the various capacitors A long press 3 s of the key connects the capacitor that is being displayed taking into account the programmed connection and reconnection times A long press 3 s of the...

Страница 56: ...rrent THD Test Parameters Display screen of the Current THD 2U 1C and 3U 1C connection L1 Current THD 3U 3C connection L2 Current THD 3U 3C connection L3 Current THD 3U 3C connection Power III Test Parameters Display screen of the Active Power III kW or MW Inductive Reactive Power III kvarL or MvarL Capacitive Reactive Power III kvarC or MvarC Apparent Power III kVA or MVA 56 Controller MASTER con...

Страница 57: ... 38 of Figure 2 dedicated to activating a fan when a pre de termined temperature is exceeded which can be programmed in 5 15 FAN is also connected to the Fan LED A fully programmable alarm relay terminals 39 40 and 41 of Figure 2 see 5 19 ENABLING ALARMS Two digital outputs fully programmable optoisolated NPN transistors terminals 34 35 and 36 of Figure 2 see 5 19 ENABLING ALARMS Controller MASTER...

Страница 58: ...AST and the master unit of 1 200 metres A maximum of 32 Controller MASTER control VAR FAST units can be connected to this bus Use an intelligent RS 232 to RS 485 network protocol converter M54020 intelligent converter to establish the communications with the master unit This converter does away with the need for the Pin 7 connection on the RS 485 side B A S A B S RS 232 USB Ethernet Profibus PC RS...

Страница 59: ...tiple logs Exception codes If the bit with greatest weight of the byte corresponding to the function in the reply of the unit is 1 this indicates that the next byte is an exception code Table 11 Exception codes Modbus communications Exception code Description 01 Incorrect function The function number is not implemented 02 Incorrect address or number of logs out of limits 03 Data error A CRC error ...

Страница 60: ...1C 31D mA L2 Active power 1E 1F 21E 21F 31E 31F W L2 Inductive Reactive Power 20 21 220 221 320 321 varL L2 Capacitive Reactive Power 22 23 222 223 322 323 varC L2 Reactive Power 24 25 224 225 324 325 var L2 Apparent Power 26 27 226 227 326 327 VA L2 Reactive Power Consumed 28 29 228 229 328 329 var L2 Reactive Power Generated 2A 2B 22A 22B 32A 32B var L2 Power Factor 1 2C 2D 22C 22D 32C 32D L2 Co...

Страница 61: ...urrent 72 73 272 273 372 373 mA Temperature 74 75 274 275 374 375 ºC 10 L1 voltage THD 7C 7D 27C 27D L2 Voltage THD 7E 7F 27E 27F L3 Voltage THD 80 81 280 281 L1 Current THD 82 83 282 283 L2 Current THD 84 85 284 285 L3 Current THD 86 87 286 287 Active energy consumed kWh 88 89 kWh Active energy consumed Wh 8A 8B Wh Inductive energy consumed kvarLh 8C 8D kvarLh Inductive energy consumed varLh 8E 8...

Страница 62: ...monic 42C 42D 4B0 4B1 mA L3 Voltage Harmonics 42E 441 4B2 4C5 10 L1 Fundamental Current Harmonic 442 443 4C6 4C7 mA L1 Current Harmonics 444 457 4C8 4DB 10 L2 Fundamental Current Harmonic 458 459 4DC 4DD mA L2 Current Harmonics 45A 46D 4DE 4F1 10 L3 Fundamental Current Harmonic 46E 46F 4F2 4F3 mA L3 Current Harmonics 470 483 4F4 507 10 Table 14 Modbus memory map measurement variables Table 3 Param...

Страница 63: ... Bit 3 Bit 2 Bit 1 Bit 0 E16 E15 E14 E13 E12 E11 E10 E09 E08 E07 E06 E05 E04 E03 E02 E01 Bit 32 Bit 31 Bit 30 Bit 29 Bit 28 Bit 27 Bit 26 Bit 25 Bit 24 Bit 23 Bit 22 Bit 21 Bit 20 Bit 19 Bit 18 Bit 16 E17 Where 0 alarm off OFF 1 alarm active ON Status of the outputs Shows the status of the 4 outputs Fan relay alarm relay and the two digital outputs It is a 16 bit variable in which each bit indicat...

Страница 64: ...lue Speed 1082 0 9600 1 19200 2 38400 2 Parity 1083 0 none 1 odd 2 even 0 Stop bits 1085 0 1 bits 1 2 bits 0 Table 18 Modbus memory map programming variables Table 4 Transformation ratios Configuration variable Address Valid data margin Default value Current primary 1090 1 10000 5 Current secondary 1091 0 1 A 1 5 A 1 Voltage primary 1092 1093 1 99999 1 Voltage secondary 1094 1095 1 99999 1 Table 1...

Страница 65: ...tage 1 Medium High voltage 0 Table 22 Modbus memory map programming variables Table 8 Display Configuration variable Address Valid data margin Default value Lighting Backlight 1125 0 Comes on when pressing a key 1 ON 2 OFF 0 Lighting level 1126 0 10 Value 10 7 Language 1127 0 Spanish 1 English 2 French 0 Advanced setup 1128 0 OFF 1 ON 0 Analogue bar 1129 0 No 1 Current 2 ITHD 3 Connected power 0 T...

Страница 66: ...mming variables Table 14 Alarm Voltage THD Configuration variable Address Valid data margin Default value Low Value 1140 0 100 5 Hi Value 1141 0 100 10 Table 29 Modbus memory map programming variables Table 15 Alarm Current x I THD Configuration variable Address Valid data margin Default value Low Value 1142 0 100 4 Hi Value 1143 0 100 5 Table 30 Modbus memory map programming variables Table 16 Al...

Страница 67: ...Address Valid data margin Default value No of operations 1152 1153 1 99999 5000 Table 36 Modbus memory map programming variables Table 22 Enabling alarms Configuration variable Address Valid data margin Default value Enable Alarm E01 1155 0 OFF 1 ON 1 Enable Alarm E02 1156 1 Enable Alarm E03 1157 1 Enable Alarm E04 1158 1 Enable Alarm E05 1159 0 Enable Alarm E06 115A 0 Enable Alarm E07 115B 0 Enab...

Страница 68: ... Alarm E14 117D 0 Output associated with Alarm E15 117E 0 Output associated with Alarm E16 117F 0 Output associated with Alarm E17 1180 0 C Deleting parameters Parameters can be deleted using Function 05 writing a relay Table 37 Modbus memory map deleting parameters Deleting parameters Action Address Value to be sent Deleting maximum values 200 FF Deleting minimum values 210 FF Deleting maximum an...

Страница 69: ... are used they must be connected to CPC3i xRS zero switching control boards The Controller MASTER control VAR FAST connection with the board will be made through the CPC NET channel in accordance with the connection table Table 38 Also consult the ter minal diagrams in Figure 2 and Figure 18 Table 38 Table showing the CPC3i to Controller MASTER control VAR FAST connection CPC3i xRS Controller MAST...

Страница 70: ... bytes DD0 DD7 Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0 DD0 thy3_np2 thy2_np2 thy1_np2 thy3_np1 thy2_np1 thy1_np1 DD1 thy3_np4 thy2_np4 thy1_np4 thy3_np3 thy2_np3 thy1_np3 DD2 thy3_np6 thy2_np6 thy1_np6 thy3_np5 thy2_np5 thy1_np5 DD3 thy3_np8 thy2_np8 thy1_np8 thy3_np7 thy2_np7 thy1_np7 DD4 thy3_np10 thy2_np10 thy1_np10 thy3_np9 thy2_np9 thy1_np9 DD5 thy3_np12 thy2_np12 thy1_np12 thy3_...

Страница 71: ...ay The password to be entered is a combination of keys It is unique and cannot be configured If it is not entered correctly the unit returns to the previous measurement screen If it is entered correctly and capacitors are connected the disconnection screen appears Disconnection screen used for the unit to automatically disconnect all the stages before entering into configuration While in this scre...

Страница 72: ... blinking it may take several minutes The capacitors are connected and disconnected during the process and this will be displayed on the screen Once the Plug Play function of the unit ends if no errors occurred during the process the results are shown by the display on two screens as follows The Plug Play function assists the user during the configuration of the unit since it automatically configu...

Страница 73: ...ors will be displayed on the screen When a parameter has been calculated correctly before the error is detected it will be displayed on the previously assigned line The errors that can occur in the Plug Play function are shown in Table 40 Table 40 Code of Plug Play errors Code Description P00 There are three possible causes that can prevent the Plug Play process from starting Some stages are cance...

Страница 74: ...aulty capacitors by means of maintenance or replacement as well as to configure all the stages in Auto mode as they come by default Conditions for the correct operation of the Plug Play function The system should be maintained with an inductive cosine of 0 62 to 0 99 throughout the process The power in the system should be stable Any major load changes 10 in less than 20 seconds would result in an...

Страница 75: ...t primary Maximum value 9999 Minimum value 1 Current secondary Possible values 1 or 5 Maximum possible current ratio 2500 NB The current ratio is the ratio between the current primary and secondary Maximum value of the current ratio x the voltage ratio 200000 If the value entered is lower than the minimum value or higher than the maximum value the backlight of the display flashes and the value ent...

Страница 76: ...ther it is inductive L or capacitive C Press the key to enter editing mode It is identified by the symbol and the blinking of the digits to be modified The key increases the digit value or shows the next option The key decreases the digit value or shows the next option The key skips to the previous digit The key skips to the next digit Press to validate the data the symbol disappears from the disp...

Страница 77: ...git value The key decreases the digit value The key skips to the previous digit The key skips to the next digit Press to validate the data the symbol disappears from the display Ton Maximum value 999 Minimum value 2 Trec Maximum value 999 Minimum value 0 If the value entered is lower than the minimum value or higher than the maximum value the backlight of the display flashes and the value entered ...

Страница 78: ...ter is used to adapt the unit to the various options for connecting the power supply and measurement cables and the current transformers to the phases of the three phase system The connection screen changes according to the connection type programmed in the preceding point Connection type 3u1C or 2u1C If a connection with a single current has been selected 3u1C or 2u1C one of the 6 possible phases...

Страница 79: ...ase PH1 L1 L2 L3 L1 PH2 L1 L2 L3 L2 PH3 L1 L2 L3 L3 PH4 L1 L2 L3 L1 inverted transformer PH5 L1 L2 L3 L2 inverted transformer PH6 L1 L2 L3 L3 inverted transformer Connection type 3u3C If the connection with three currents has been selected 3u3C each current is associated with its voltage and the direction of the current is indicated in this screen d direct i reverse Press the key to enter editing ...

Страница 80: ... Controller MASTER control VAR FAST 6 or Controller MASTER control VAR FAST 12 it can be configured with up to 6 or up to 12 outputs Press the key to enter editing mode It is identified by the symbol and the blinking of the digits to be modified The key shows the next option The key shows the previous option Press to validate the data the symbol disappears from the display Press the key to access ...

Страница 81: ...eps are connected or disconnected at the same time without following a sequence This operation is faster than the FCP SIM no operation the unit stays in simulation mode 1 1 In SIM mode the measurement screens simulate the outputs that the unit would connect or disconnect but it doesn t actually do so To avoid confusion on the measurement screens the name of the screen is switched with the literal ...

Страница 82: ...500 5 0 05 0 06 0 07 0 10 0 12 0 14 0 19 0 24 0 29 0 36 0 38 2000 5 0 05 0 07 0 09 0 11 0 14 0 18 0 22 0 27 0 28 2500 5 0 06 0 07 0 09 0 12 0 14 0 17 0 22 0 23 3000 5 0 05 0 06 0 07 0 10 0 12 0 14 0 18 0 19 4000 5 0 05 0 07 0 09 0 11 0 14 0 14 If the capacitor power reference of 440 V is used for a 400 V network voltage the table is Table 43 Table 43 C K factor table 2 CT Ratio Ip Is Power of the ...

Страница 83: ...ary Example In a 400 V unit the smallest capacitor is of 60 kvar with a current transformer having a ratio of 500 5 and the calculation would be made as follows Current of the smallest capacitor Ic A IC 6 8 6 400 3 60000 K Factor 100 5 500 K The C K value is 0 866 If the power of 60 kvar is referenced at 440 V it should be multiplied by Vgrid2 4402 in which case the C K value of the previous examp...

Страница 84: ...ximum value or with the last value validated Press the key to access the next programming step If no keys are pressed for 5 minutes the unit switches to the simulation screen 5 27 SIMULATION SCREEN 5 10 ADVANCED SETUP In this point it is possible to decide whether to access the advanced setup menu If the YES option is selected the next programming step will be the voltage transformation ratio 5 11...

Страница 85: ...he key decreases the digit value The key skips to the previous digit The key skips to the next digit Press to validate the data the symbol disappears from the display Voltage primary Maximum value 99999 Minimum value 1 Voltage secondary Maximum value 99999 Minimum value 1 Maximum possible voltage ratio 1000 NB The voltage ratio is the ratio between the primary and secondary voltage Maximum value o...

Страница 86: ...always disconnected On NC Stage forced to ON always connected but the system does not take into account its connected power By default all the stages are configured as AUTO On the measurement screens the forced states of the stages are shown by activating the bottom line of the capacitor status bar 4 4 1 STATUS OF THE CAPACITORS Press the key to enter editing mode It is identified by the symbol an...

Страница 87: ...inutes The light level is also configured between 0 and 100 when the display is on The display language options are as follows ESP Spanish EnG English FrA French The key increases the digit value or shows the next option The key decreases the digit value or shows the next option The key skips to the previous parameter The key skips to the next parameter Press to validate the data the symbol disapp...

Страница 88: ...of power connected to the capacitor bank relative to the total power THdI the Current THD of each phase I the current of each one of the phases nO no parameters are displayed The key shows the next option The key shows the previous option Press to validate the data the symbol disappears from the display Press the key to access the next programming step If no keys are pressed for 5 minutes the unit...

Страница 89: ...it value or shows the next option The key decreases the digit value or shows the next option The key skips to the previous parameter The key skips to the next parameter Press to validate the data the symbol disappears from the display Maximum value 80ºC Minimum value 0ºC If the value entered is lower than the minimum value or higher than the maximum value the backlight of the display flashes and t...

Страница 90: ...tion The key decreases the digit value or shows the next option The key skips to the previous digit or the previous parameter The key skips to the next digit or the next parameter Press to validate the data the symbol disappears from the display If the value entered is lower than the minimum value or higher than the maximum value the backlight of the display flashes and the value entered is replac...

Страница 91: ...ases the digit value or shows the next option The key skips to the previous digit or the previous parameter The key skips to the next digit or the next parameter Press to validate the data the symbol disappears from the display If the value entered is lower than the minimum value or higher than the maximum value the backlight of the display flashes and the value entered is replaced with the minimu...

Страница 92: ...ers can be deleted n maximum and minimum values E energies C number of connections of the stages The key shows the next option The key shows the previous option The key skips to the previous parameter The key skips to the next parameter Press to validate the data the symbol disappears from the display Press the key to access the next programming step If no keys are pressed for 5 minutes the unit s...

Страница 93: ...r alarm Association with a relay or digital output alarm reLay the activation of the alarm is associated with the alarm relay d1 the activation of the alarm is associated with digital output 1 d2 the activation of the alarm is associated with digital output 2 no not associated with any relay or digital output The key shows the next option The key shows the previous option The key skips to the prev...

Страница 94: ...stages The unit does not return to its normal operating status until the cause for the alarm disappears The key increases the digit value The key decreases the digit value The key skips to the previous digit The key skips to the next digit Press to validate the data the symbol disappears from the display Overvoltage alarm Maximum value 99999 V Minimum value 0 V No voltage alarm Maximum value 99999...

Страница 95: ...citive C The key increases the digit value or shows the next option The key decreases the digit value or shows the next option The key skips to the previous digit The key skips to the next digit Press to validate the data the symbol disappears from the display Current Maximum value 9999 A Minimum value 0 A cos φ Maximum value 1 00 Minimum value 0 80 If the value entered is lower than the minimum v...

Страница 96: ...s this value for 30 seconds alarm E08 is triggered and if alarm E12 is enabled the Controller MASTER control VAR FAST unit enters Disconnection status and activates alarm E12 If the unit falls back under the Lo value for 10 minutes it deactivates the alarms and returns to the normal operating status In the No Connection status the unit does not connect the stages but also does not disconnect them ...

Страница 97: ...o be considered as the setpoint For example If you want to program a Lo setpoint value when exceeding a harmonic current of 200 A measured by the regulator program 00200 directly in this section The parameters to be configured are The Lo value when the unit exceeds this value for 30 minutes alarm E09 is triggered and if alarm E11 is enabled the Controller MASTER control VAR FAST unit enters No Con...

Страница 98: ...ve which the temperature alarm E10 is activated can be configured The alarm must be enabled 5 19 ENABLING ALARMS Press the key to enter editing mode It is identified by the symbol and the blinking of the digits to be modified The parameters to be configured are The Lo value when the unit exceeds this value for 30 minutes alarm E09 is triggered and if alarm E11 is enabled the Controller MASTER cont...

Страница 99: ...Press to validate the data the symbol disappears from the display Lo Value and HI Value Maximum value 80ºC Minimum value 0ºC If the value entered is lower than the minimum value or higher than the maximum value the backlight of the display flashes and the value entered is replaced with the minimum or maximum value or with the last value validated Press the key to access the next programming step I...

Страница 100: ...isplayed on the screen If the unit has a Sim type operation configured see section 5 8 PROGRAM the responsible stage s search process will not be done even if it is enabled to do so Enable stages in this parameter the stages that were disabled by this alarm are enabled again YES option The key increases the digit value and the next option The key decreases the digit value and the previous option T...

Страница 101: ...ey decreases the digit value The key skips to the previous digit The key skips to the next digit Press to validate the data the symbol disappears from the display Maximum value 99999 k Minimum value 1 k If the value entered is lower than the minimum value or higher than the maximum value the backlight of the display flashes and the value entered is replaced with the minimum or maximum value or wit...

Страница 102: ...s if the key is pressed for 3 seconds or if no keys are pressed for 5 minutes or to return to the configuration screens when pressing any of the other keys The screen shows the following information Measurement of the cos φ Three phase reactive power The word STOP as a reminder that the unit is still not in measurement status Simulation of the steps that would be connected upon entering measuremen...

Страница 103: ...easurement circuit By means of an earth leakage transformer with a ratio of 500 turns Nominal current of the secondary 3 mA Current measurement margin 10 mA to 1 5 A Minimum measurement current Istart 10 mA Measurement accuracy UNE EN 61557 12 Voltage measurement 0 5 1 digit Current measurement 0 5 1 digit Active power measurement 0 5 2 digits Reactive power measurement 1 2 digits Active energy me...

Страница 104: ...200 9600 19200 38400 Stop bits 1 2 Parity none even odd Environmental features Operating temperature 10ºC to 55ºC Storage temperature 20ºC to 70ºC Relative humidity with no condensation 5 95 Maximum altitude 2 000 m Protection degree IP31 Front panel IP51 Mechanical features Dimensions Figure 19 144x144x78 mm Weight 575 g Enclosure Self extinguishing V0 plastic Assembly Panel 144 144 7 21 75 71 10...

Страница 105: ...E EN 61000 2007 Electromagnetic compatibility CEM Part 6 Generic standards Sec tion 2 Generic immunity standards for industrial environments UNE EN 61000 6 2 2005 Electromagnetic compatibility CEM Part 6 4 Generic standards Emissions standard for industrial environments UNE EN 61000 6 4 2005 105 Instruction Manual Controller MASTER control VAR FAST ...

Страница 106: ...er installation or improper usage of the unit Consequently this guarantee does not apply to failures occurring in the following cases Overvoltages and or electrical disturbances in the supply Water if the product does not have the appropriate IP classification Poor ventilation and or excessive temperatures Improper installation and or lack of maintenance Buyer repairs or modifications without the ...

Страница 107: ...107 Instruction Manual Controller MASTER control VAR FAST ...

Страница 108: ...LIFASA INTERNATIONAL CAPACITORS SA C Vallès 32 Pol Ind Can Bernades 08130 Santa Perpètua de Mogoda Barcelona ESPAÑA Tel 34 935 747 017 Fax 34 935 448 433 www lifasa es info lifasa es ...