7. Indoor unit installation.
• Hook the indoor unit onto the upper portion of
installation plate. (Engage the two hooks of the
rear top of the indor unit with the upper edge of
the installation plate.)
Ensure the hooks are properly seated on the
installation plate by moving it in left and right.
8. Connecting the pipings to the indoor unit.
• Align the center of the pipings and sufficiently
tighten the flare nut with fingers.
• Finally, tightening the flare nut with torque wrench
until the wrench clicks.
Wrench tightening the flare nut with torque
wrench, ensure the direction for tightening follows
the arrows on the wrench.
9. Wrap the insulation material around the con-
necting portion.
Pipe Size
Torque
Liquid Side (1/4")
1.8kg.m
Gas Side (3/8")
4.2kg.m
Gas Side (1/2")
5.5kg.m
Press the lower left and right side of the unit against the
Installation Plate until the hooks engages with their slots
(sound click).
Connecting cable
Drain hose
Spanner
Flare nut
Indoor unit tubing
Torque wrench
Pipings
Plastic Bands
Wrap the insulation material around the connecting
portion.
Instulation material