- 14 -
• Cooling Mode with the Sleep Mode
The setting temperature will be raised by 1°C 30minutes later and by 2°C 1 hour later.
The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
• Heating Mode with the Sleep Mode.
The operation will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
Intake Air temp.
COMP. ON
(SET TEMP. +0.5°C
COMP. OFF
(SET TEMP. -0.5°C
INDOOR FAN SPEED
COMPRESSOR
ON
OFF
OFF
ON
ON
Low
Low
Low
Low
1
°C
1
°C
Low
30 minutes
30 minutes
More than
3 minutes
More than
3 minutes
SETTING TEMP. +3°C
(COMPRESSOR OFF)
SETTING TEMP.
(COMPRESSOR ON)
INDOOR FAN SPEED
COMPRESSOR
Med.
ON
ON
ON
Low or OFF
Low or OFF
Low or OFF
OFF
OFF
OFF
Med.
Med.
Содержание LS-B0760CM/B0760HM
Страница 59: ... 59 Schematic Diagram 7K 9K 11K 12K 14K BTU Cooling Only Series ...
Страница 60: ... 60 7K 9K 12K BTU Cooling Heating Series ...
Страница 71: ...P NO 3828AR7036F Printed in Korea ...