1. Heating Model
2.Cooling Model
1. Protection of the eveporator pipe from frosting
If the temperature of the indoor pipe is below 0°C after 7 mins from starting the compressor, the compressor
and the outdoor fan is stopped, and then after 3 mins delay of the compressor and the temperature of the indoor
pipe is over 7°C, the compressor and the outdoor fan is reoperated.
2. Thermistor Cut Off of Short
Cut Off/Short : Blinks on and off the operation mode LED. (0.5 sec ON/3 sec OFF)
Display Function
- 20 -
Self-diagnosis Function
Operation Indicator
• Cooling, Soft Dry, Fan, Heating
• Timer Mode
• Sleep Mode
• Hot-start, Deice
Timer Indicator
Sleep Timer Indicator
Deicer Indicator
Operation Indicator
Timer Indicator
Sleep Timer Indicator
Outdoor unit operation
• Cooling, Soft Dry, Fan, Heating
• Timer Mode
• Sleep Mode
• Outdoor Unit Operating or not
OUT
DOOR