Thermal Error
Condition.
The resistance of thermistor not
normally out put.
Yes
Yes
Yes
Yes
Yes
No
No
No
Is the connector
connected to main PCB
assembly disconnected or
disassembled? (RD6)
Is the connector
connected to heater
assembly disconnected or
disassembled?
Is the thermistor operated
properly?
(range is 12~13kΩ)
Is the resistor between
connectors out of range?
(RD6 pin2 ~ pin3)
- After remove the
connector from the PCB,
check the resistor.
(range is 12~13kΩ)
Reconnect
or repair the
connector.
Reconnect
or repair the
connector.
Replace the
thermistor.
Replace the
main PCB
assembly.
Is displayed?