Drain Error
Condition.
Not fully drained out in spite of 5 min.
drain operation.
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
Motor rpm is not increased.
Motor rpm is
increased.
Does the drain motor operate?
Check the rpm of drain motor by the
test Mode.
Is the connector connected to
main PCB assembly disconnected
or disassembled? (YL3)
Is the voltage between connectors
out of range? (YL3 pin1~pin2~pin3)
- After remove terminal position
assurance (TPA) of connector,
check the voltage when water is
drained. (The voltage is over 12V DC)
Is the resistance vales between
connectors out of range?
(range is 4~5Ω)
(Yellow 3P, pin1~pin2~pin3)
Is the connector connected to
drain motor disconnected
or disassembled?
Reconnect or
repair the connector.
Replace the main
PCB assembly.
Replace the drain
motor
Reconnect or
repair the connector.
Is the filter clogged?
Clean the filter
Remove the cause of kink
or block.
Remove the cause of kink
or block.
Is the outer drain hose
kinked or blocked or frozen?
Is the inner drain hose
and drain case
kinked or blocked or frozen?
Is displayed?
Содержание LDF7774BB
Страница 2: ......
Страница 14: ...For Authorized Service Technician 14 5 PROGRAM CHART SCHEMATIC DIAGRAM LDF8874 LDF8764 Program Chart ...
Страница 15: ...For Authorized Service Technician 15 LDF7774 LDS5774 Program Chart ...
Страница 67: ...For Authorized Service Technician 67 ...
Страница 68: ...For Authorized Service Technician 68 P No MFL37554813 ...