For Authorized Service Technician
For Authorized Service Technician
- 11 -
LDF8874/LDF8764
3-3. TEST MODE
BUTTON
The number of
pushing button
Top Display
Load and Checking points
Door open/
closed
Remark
Load
LED lighting
Auto+
Heavy+POWER
1 TIME
N03/U00/D00
(Version)
All LEDs are lighting
Either
DELAY START
1 TIME
Steam
Generator
Temp(
℃
)
Steam
Generator
Thermistor
All LEDs
Closed
2 TIME
N02
Fan Motor
All LEDs
Closed
3 TIME
N03
Dispenser
All LEDs
Closed
4 TIME
Soil Level
Soil Sensor
All LEDs
Closed
5 TIME
Steam
Generator
Water Level
Water Level
All LEDs
Closed
6 TIME
Sump
Temp(
℃
)
Sump
Thermistor
All LEDs
Closed
7 TIME
N07
Steam
Generator
Inlet Valve
All LEDs
Closed
8 TIME
Pump RPM
Drain Pump
All LEDs
Either
9 TIME
Frequency
Inlet Valve
All LEDs
Closed
10 TIME
Motor RPM
Washing Pump
All LEDs
Closed
11 TIME
Un Cr LO
Vario Valve
All LEDs
Closed
12 TIME
-
Auto Off
All LEDs
Closed
Normal water level : 170~260
Pure water : more than 130
H: High water level / L: Low water level
CHECK PROGRAM