![LG LDF7774BB Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/lg/ldf7774bb/ldf7774bb_service-manual_1896432036.webp)
For Authorized Service Technician
- 36 -
Nozzle(Vario) Error
Condition.
The position of vario cam is not
properly.
Yes
Yes
Yes
Yes
Yes
No
No
Check the connectors below.
Is the connector
disconnected or disassembled?
(BL4 : vario motor,
NA8 : Vario S/W sensing)
Does the vario S/W assembled properly?
Is the vario motor operated properly?
(range is 12~15K Ω)
Reassemble
vario S/W.
Replace the
vario motor.
Reconnect
or repair the
connector.
Does the PCB assembly working
properly?
When Door is closed,
check the voltage between
BL4 pin1 and BL4 pin4.
-. Vario motor stop working
: 120V AC
-. Vario motor stop stop : 0~1V
Is displayed?