System Set-Up
70
Hydro Kit
• DHW time setting
Determine following time duration : operation time of DHW tank heating, stop time of DHW tank
heating, and delay time of DHW tank heater operating.
- Active time : This time duration defines how long time DHW tank heating can be continued.
- Stop time : This time duration defines how long time DHW tank heating can be stopped. It is also
regarded as time gap between DHW tank heating cycle.
Th On
Th Off
0
-0.5 ℃
1.5 ℃
1
-1 ℃
2 ℃
2
-2 ℃
3 ℃
3
-3 ℃
4 ℃
• TH on/off Variable, heating air
Setting Thermal on/off Air Temperature gap in heating mode
• TH on/off Variable, heating water
Setting Thermal on/off Water Temperature gap in heating mode
• TH on/off Variable, cooling air
Setting the step value to adjust air temperature gap in cooling mode
Th On
Th Off
0
0.5 ℃
-0.5 ℃
1
1 ℃
-1 ℃
2
2 ℃
-2 ℃
3
3 ℃
-3 ℃
Th On
Th Off
0
0.5 ℃
-0.5 ℃
1
1 ℃
-1 ℃
2
2 ℃
-2 ℃
3
3 ℃
-3 ℃
Th On
Th Off
0
-2 ℃
2 ℃
1
-3 ℃
3 ℃
2
-4 ℃
4 ℃
3
-1 ℃
1 ℃
• TH on/off Variable, cooling water
Setting the step value to adjust water temperature gap in cooling mode
Содержание Hydro Kit
Страница 77: ......