System Set-Up
62
Hydro Kit
Function text inside
remote
Range
Short explanation
Mid Temp.
High Temp.
Cooling / Heating only
mode
- Set
- Release (Default)
Oil recovery option Type 0, 1 (Default 0)
Setting the operation mode lock function.
Water supply off temp.
during cooling
- Water stop temperature
16 °C ~ 25 °C (16 ℃ default)
- FCU use/not use (use default)
N/A
When cooling the floor, it is necessary to
stop the supply of cold water to prevent
bottom dew.
Outdoor temp. for auto
mode
- Upper limitation 10 °C ~ 20 °C
(15 ℃ default)
- Lower limitation -20 °C ~ 5 °C
(-10 ℃ default)
- Upper limitation 10 °C ~ 20 °C
(15 ℃ default)
- Lower limitation -20 °C ~ 5 °C
(-10 ℃ default)
Setting outdoor Min/Max temperature for
auto mode.
Indoor air temp. for auto
mode
- Upper limitation 20 °C ~ 30 °C
(21 ℃ default)
- Lower limitation 16 °C ~ 19 °C
(16 ℃ default)
- Upper limitation 20 °C ~ 30 °C
(21 ℃ default)
- Lower limitation 16 °C ~ 19 °C
(16 ℃ default)
Setting indoor Min/Max temperature for
auto mode
LWT for auto mode
- Upper limitation 35 °C ~ 50 °C
(50 ℃ default)
- Lower limitation 20 °C ~ 34 °C
(20 ℃ default)
- Upper limitation 65 °C ~ 80 °C
(80 ℃ default)
- Lower limitation 40 °C ~ 54 °C
(50 ℃ default)
Setting heating flow Min/Max temperature
for auto mode
Tank disinfection
setting 1
N/A
- Disable(default), Enable
Setting start/maintain time for
pasteurisation
N/A
- Sun. , Mon. , … , Fri. , Sat.
(Default : Fri.)
Setting start/maintain day for
pasteurisation
N/A
- Start Time : 00 ~ 23
(Default : 23)
Setting start/maintain time for
pasteurisation
Tank disinfection
setting 2
N/A
- 40 °C ~ 80 °C (70 °C Default)
The temperature set point during
disinfection operation.
N/A
- 5 min ~ 60 min (10 min Default)
When the distinfection tank temperature is
reached, the BSH continu to operate
regarding this timer.
N/A
- 1~12 hours (1 hour default)
When the disinfection tank temperature is
not reached, stop disinfect regarding this
timer.
Tank setting1
N/A
Function for AWHP except for Hydro Kit.
When it is necessary to change the
weight of heating water source in the hot
water tank depending on the user's
environment. The value for determining
the minimum temperature for maintaining
the hot water.
N/A
Function for AWHP except for Hydro Kit.
When it is necessary to change the
weight of heating water source in the hot
water tank depending on the user's
environment. Upper temperature limit for
outdoor unit.
Tank setting2
N/A
Function for AWHP except for Hydro Kit.
Hysterisis value to maintain the desired
temperature of hot water.
- 00 : Perform hot water
- 01 : Perfom heating floor
Setting heating demand priority.