23*
Inverter Compressor DC
Link Low Voltage
Error
No.
Error Type
Error Point
Main Reasons
DC Voltage isn't charged
after starting relay on
1. DC Link terminal misconnection/terminal
contact fault
2. Starting relay damage
3. Condenser damage
4. Inverter PCB assembly damage
(DC Link voltage sensing part)
5. Input voltage low
■
Error Diagnosis and Countermeasure Flow Chart
Is input voltage normal?
No
Yes
Yes
Yes
Recheck power and installation condition
Check
R~S / S~T / T~R phase voltage is 380V 10%
R~N / S~N / T~N phase voltage is 220V 10%
→
Check connection condition and wiring if power is
abnormal
Is inverter PCB assembly
power connection normal?
No
Check connection between inverter PCB assembly and
bridge diode(misconnection, disconnection)
→
wiring again if abnormality found
Is inverter PCB assembly normal?
No
Check inverter PCB assembly IPM normality
→
Replace inverter PCB assembly