Bring Tools and Materials
In addition to the tools and materials provided by ChargePoint in product crates, an approved
installer needs:
•
Lifting equipment (forklift or crane)
•
Lockout/tag out equipment
•
Step ladder
•
Cut-resistant gloves
•
Safety glasses
•
Head-mounted flashlight
•
Torque wrenches capable of 4 to 95 Nm (3 to 70 ft-lbs)
•
10 mm (3/8 in) deep socket wrench
•
18 mm (11/16 in) wrench
•
24 mm (15/16 in) wrench (x2)
•
8 mm (5/16 in) nut driver
•
10 mm (3/8 in) nut driver
•
5 mm (3/16 in) hex driver
•
#2 Phillips screwdriver with long handle
•
Cellular signal detection device, such as a Snyper, Octopus, or similar
•
Standard electrical equipment such as wire cutter, wire stripper, and cable ties
•
Level
•
Isopropyl wipes
•
Wire brush
•
If not already installed for this site, and if applicable, shunt trip wiring: size 0.08 to 2.5 mm² (28
to 14 AWG), fine stranded or solid
•
If not already installed for this site, AC and ground conductors with these specifications:
Voltage Rating
Temperature Rating
Maximum Conductor Size for Terminals
EU non-armored: 600/1000 V
90°C
35 mm
2
EU armored: 600/1000 V
90°C
35 mm
2
multi-core
NA: 600 V
90°C
2 AWG