Example configurations
Leuze electronic
CML 730-PS
96
11.8 Example configuration – Reliable beam penetration through opaque films
Function reserve mode
Target function reserve
Select Main Settings > Sensitivity Setting > Function Reserve > Target Function Reserve
Set the following configuration:
Nominal value: 999 (maximum value)
Switching threshold: 40% (at least 30%; the smaller the switching threshold is, the higher the beam pen
-
etration power will be)
Hysteresis: 20% (at least 10%; the smaller the switching hysteresis is, the higher the beam penetration
power will be)
Figure 11.3: Reliable beam penetration through opaque films
Objects behind the film are detected reliably if they are 10 mm or larger in size.
Function reserve mode
Tx/Rx power
Select Main Settings > Sensitivity Setting > Function Reserve > Tx/Rx Power
The optimum parameter settings can only be determined directly in the application.
Determine the settings by trial and error in your application.
NOTICE
Halation effects can influence the measurement!
Halation effects may be a hindrance depending on the position of the film and of the objects to be
detected.
Reduce the transmitting power while maintaining the same receiving sensitivity setting.