Electrical connection
Leuze electronic
CML 730-PS
54
1
Receiver (R)
2
Transmitter (T)
3
Connection cable (M12 socket, 8-pin),see table 17.3
4
Synchronization cable (M12 plug/socket, 5-pin), see table 17.2.2
Figure 7.5: Electrical connection – CML 700i with IO-Link/analog interface
Connect connection X2 to connection X3 using the appropriate synchronization cable.
Connect connection X1 to the voltage supply and the control using the appropriate connection cable.
7.5.1 X1 pin assignment – CML 700i with analog interface
8-pin, M12 plug (A-coded) is used for connecting to PWR IN/digital IO and analog interface.
1
M12 plug (8-pin, A-coded)
Figure 7.6: X1 connection – CML 700i with analog interface
Table 7.2:
X1 pin assignment – CML 700i with analog interface
PWR IN/OUT
X1
X
2
X3
1
2
3
4
1
Pin
X1 - Logic and power on the receiver
1
VIN: +24 V DC supply voltage
2
IO 1: input/output (configurable)
Ex works: teach input
3
GND: ground (0 V)
4
C/Q: IO-Link communication
5
IO 2: input/output (configurable)
Ex works: trigger input