Starting up the device - IO-Link interface
Leuze electronic
CML 730-PS
74
10
Starting up the device - IO-Link interface
The configuration of an IO-Link interface involves the following steps on the receiver control panel and the
IO-Link master module of the control-specific configuration software.
General prerequisites:
• The measuring light curtain has been mounted (see chapter 6) and connected (see chapter 7) cor
-
rectly.
• The basic configuration has been performed (see chapter 8).
10.1 Defining IO-Link device configurations on the receiver control panel
The parameters for the IO-Link interface are configured with the process data length (PD length) and the
data storage configurations. By changing the process data length, the light curtain receives a new IO-Link
device ID and must be operated with the compatible IO Device Description (IODD).
The structure of these configurations in the receiver control panel menu is as follows:
Select Main Settings > IO-Link > PD Length.
The PD length is configured.
Select Main Settings > IO-Link > Data Storage.
Event: The light curtain sends changes made to system-relevant parameters which can be transferred,
directly to the IO-Link master module.
Other possible configuration steps are performed via the
Sensor Studio
configuration software (see
chapter 12).
Process mode is configured via the IO-Link master module of the control-specific software.
10.2 Defining configurations via the IO-Link master module of the PLC-specific software
General prerequisites:
• The measuring light curtain has been mounted (see chapter 6) and connected (see chapter 7) cor
-
rectly.
• The basic configuration has been performed (see chapter 8).
• The IO-Link-specific basic configurations have been performed.
• IO-Link PD length selected
NOTICE
Changes take effect immediately!
The changes take effect immediately (without restarting).
The IODD file is supplied with the device and is available for download at www.leuze.com.
Factory settings:
PD length: 8 bytes
Data storage: active
Level 0
Level 1
Level 2
Description
Main Settings
Commands
Operation Settings
IO-Link
PD-Length
8 bytes
32 bytes
Data Storage
Inactive
Active
Event