Troubleshooting
Leuze electronic
CML 730-PS
110
RxS 0x23F4 Configuration error - blanking.
Upper adjacent beam selected for beam “i” and lower adja
-
cent beam selected for beam “i+1”.
Check the configuration of
the blanking parameters
Reset device to factory set
-
tings.
RxS 0x23F5 Configuration error - blanking.
Upper adjacent beam selected for beam “i” and no adja
-
cent beam exists.
Check the configuration of
the blanking parameters
Reset device to factory set
-
tings.
RxS 0x23F6 Configuration error - blanking.
Lower adjacent beam selected for beam “i” and no adja
-
cent beam exists.
Check the configuration of
the blanking parameters
Reset device to factory set
-
tings.
RxS 0x23F7 Configuration error - blanking.
Overlapping of the blanking areas.
Check the configuration of
the blanking parameters
Reset device to factory set
-
tings.
RxS 0x23F8 Configuration error - blanking.
Start beam > end beam.
Check the configuration of
the blanking parameters
Reset device to factory set
-
tings.
RxS 0x23FA Configuration error – time behavior.
The delay time is greater than the trigger cycle time/mea
-
surement cycle time.
Check the time behavior
setting (see chapter 16.2).
Reset device to factory set
-
tings.
RxS 0x23FB Configuration error – time behavior.
The pulse width is greater than the trigger cycle time.
Check the time behavior
setting (see chapter 16.2).
Reset device to factory set
-
tings.
RxS 0x23FC Configuration error – time behavior.
The measurement cycle time is greater than the trigger
cycle time.
Check the time behavior
setting (see chapter 16.2).
Reset device to factory set
-
tings.
Error code
Description
Measures