Starting up the device - IO-Link interface
Leuze electronic
CML 730-PS
83
Analog device settings (group 12)
IO Function
80
81
82
2
unsigned 8
RW
0 … 6
0: Deactivated
1: Trigger input
2: Teach input
3: Area output
4: Warning output
5: Trigger output
6: Validation output
Operating mode of time
module
80
81
82
3
unsigned 8
RW
0 … 4
0
0: Deactivated
1: Start-up delay
2: Switch-off delay
3: Pulse stretching
4: Pulse suppression
Time constant for
selected function
80
81
82
4
unsigned 8
RW
0 … 65,000
0
Unit: ms
Area mapping 32 … 25
80
81
82
5
unsigned 8
RW
0
Area mapping 24 … 17
80
81
82
6
unsigned 8
RW
0
Area mapping 16 … 09
80
81
82
7
unsigned 8
RW
0
Area mapping 08 … 01
80
81
82
8
unsigned 8
RW
0
Parameter
Index
Sub-
index
Data type
Access Value range
Default Explanation
In this group, various parameters can be used to set the analog device configurations, e.g, the
configuration of the analog output level and how the evaluation function that is represented on
the analog output is selected.
Parameter
Index
Sub-
index
Data type
Access Value range
Default Explanation
Signal level
88
0
unsigned 8
RW
0 … 6
0
Configuration of the analog output level: voltage:
0 … 5 V voltage: 0 … 10 V voltage: 0 … 11 V cur
-
rent: 4 … 20 mA current: 0 … 20 mA current:
0 … 24 mA
0: Not active
1: Voltage: 0 … 5 V
2: Voltage: 0 … 10 V
3: Voltage: 0 … 11 V
4: Current: 4 … 20 mA
5: Current: 0 … 20 mA
6: Current: 0 … 24 mA
Evaluation function
89
0
record 48 bit,
isolated
access to
sub-index not
possible
RW
Selection of the evaluation function that is repre
-
sented on the analog output: first interrupted/not
interrupted beam (FIB/FNIB), last interrupted/not
interrupted beam (LIB/LNIB), total of interrupted/not
interrupted beams (TIB/TNIB)
Analog Function
89
1
(bit
offset
= 40)
unsigned 8
RW
0 … 6
0
0: No function (NOP)
1: First interrupted beam (FIB)
2: First not interrupted beam (FNIB)
3: Last interrupted beam (LIB)
4: Last not interrupted beam (LNIB)
5: Total of interrupted beams (TIB)
6: Total of not interrupted beams (TNIB)
Start beam of analog
measuring area
89
2
(bit
offset
= 16)
unsigned 16
RW
1 … 1774
1
End beam of analog
measuring area
89
3
(bit
offset
= 16)
unsigned 16
RW
1 … 1774
1