Electrical connection
Leuze electronic GmbH + Co. KG
BCL 308
i
65
Figure 7.6: BCL 308
i
- MK 308 terminal hood with spring-cage terminals
Cable fabrication and shielding connection
Remove approx. 78 mm of the connection cable sheathing. 15 mm of sheath of the shielded line must be
freely accessible.
Figure 7.7: Cable fabrication for MK 308 terminal hood
The shield is automatically contacted when the cable is lead into the metal screw fitting and fastened when
the cord grip is closed. Then lead the individual wires into the terminals according to the diagram. Wire end
sleeves are not necessary.
NOTE
The integrated parameter memory for the simple replacement of the BCL 308
i
is located in the
MK 308. In the integrated parameter memory, both the settings and the network address are
saved and transmitted to a new device.
NOTE
In the case of Ethernet linear topology, the network is interrupted when the BCL 308
i
is removed
from the MK 308.
NOTE
Dimensioned drawing on see chapter 5.4 "Reading field curves / optical data" on Page 41.
Terminal hood
MK 308
SERVICE
2
1
3
5
4
GND
D+
D-
VB
ID
Mini-B USB socket
(behind protective cap)