Fast commissioning / operating principle
Leuze electronic GmbH + Co. KG
BCL 308
i
13
ME 308 103 connection hood with M12 connection cables
Figure 3.2: BCL 308
i
- ME 308 103 connection hood with M12 connection cables
NOTE
The shielding connection is done via the M12 connector housing.
NOTE
The integrated parameter memory for the simple replacement of the BCL 308
i
is located in the
ME 308 103. In the integrated parameter memory, both the settings and the network address are
saved and transmitted to a new device.
NOTE
In the case of Ethernet line topology, the network is interrupted when the BCL 308
i
is removed
from the ME 308 103.