Fast commissioning / operating principle
Leuze electronic GmbH + Co. KG
BCL 308
i
12
MS 308 connector hood with 2 integrated M12 connectors
Figure 3.1: BCL 308
i
- MS 308 connection hood with M12 connectors
NOTE
The shielding connection is done via the M12 connector housing.
NOTE
The integrated parameter memory for the simple replacement of the BCL 308
i
is located in the
MS 308. In the integrated parameter memory, both the settings and the network address are
saved and transmitted to a new device.
NOTE
In the case of Ethernet linear topology, the network is interrupted when the BCL 308
i
is removed
from the MS 308.