Online commands
220
BCL 548
i
Leuze electronic
Determining parameter set difference to default parameters
Command
’PD’
Description
This command outputs the difference between the default parameter set and the oper-
ating parameter set or the difference between the default parameter set and the per-
manent parameter set.
Comment
:
The reply supplied by this command can e.g. be directly used for programming a device
with factory settings, whereby this device receives the same configuration as the
device on which the PD-sequence was executed.
Parameter
’PD<P.set1><P.set2>
’
<P.set1>
Parameter data set which is to be copied,
unit [dimensionless]
’0’
Parameter data set in permanent memory
’2’
Default or factory parameter set
<P.set2>
Parameter set to which the data is to be copied, unit [dimensionless]
’0’
Parameter data set in permanent memory
’3’
Operating parameter data set in volatile memory
Permissible combinations here include:
’20’
Output of the parameter differences between the default and the
permanently saved parameter set
’23’
Output of the parameter differences between the default parameter
set and the operating parameter set saved in volatile memory
’03’
Output of the parameter differences between the permanent param-
eter set and the operating parameter set saved in volatile memory
Acknowledgment
positive
PT<BCC><PS type><Status><Adr.><P.value adr.><P.va1>…
[;<Adr.><P.value adr.>]
<BCC>
’0’
No check digit
’3’
BCC mode 3
<PS type>
’0’
Values stored in flash memory
’3’
Operating values stored in RAM
<Status>
’0’
No further parameters
’1’
Additional parameters follow
<Adr.>
Relative address of the data within the data set
’aaaa’
Four-digit, unit [dimensionless]
<P.value>
Parameter value of the -bb- parameter stored at this address. The
parameter set data is converted from HEX format to a 2-byte-ASCII
format for transfer.