Commissioning and configuration
128
BCL 548
i
Leuze electronic
10.4.7.4 UDP
The BCL 548
i
requires from the user the IP address and the port number of the communi-
cation partner. Correspondingly, the host system (PC / PLC) now also requires the set
IP address of the BCL 548
i
and the selected port number. By assigning these parameters,
a socket is formed via which the data can be sent and received.
Activate the UDP protocol
Also set the following values:
• IP address of the communication partner
• Port number of the communication partner
The corresponding adjustment options can be found:
• Via webConfig:
• Configuration -> Communication -> Host communication
• Or, alternatively, via the display
All other parameters required for the reading task, such as setting the code type and number
of digits, etc., are set using the engineering tool of the PLC with the aid of the various avail-
able modules (see chapter 10.5).
Parameter 1
Parameter handling
Decoder table
Digital SWIO
Ethernet
In the parameter menu, use the
buttons to select the
Ethernet
menu item.
Press the enter button to enter the
Ethernet
menu.
Ethernet
Ethernet interface
o HOST communication
Use the
buttons to select the
Host communication
menu
item.
Press the enter button to enter the
Host communication
menu.
Host communication
TcpIP
o UDP
Use the
buttons to select the
UDP
menu item.
Press the enter button to enter the
UDP
menu.
UDP
o Activated
IP address
Port number
Use the
buttons to successively select the
Activated
,
IP
address
and
Port number
menu items and set the desired val-
ues.