Commissioning and configuration
190
BCL 548
i
Leuze electronic
Input data length
2 bytes
Output data
Output data length
1 byte
Switching output 3
Comparison state
toggle bit
(Event Counter)
If "SWOUT switches several times"
was configured as comparison mode,
this bit is toggled each time the event
counter is exceeded.
Indicates whether the event counter
has reached the set comparative
value.
1.5
Bit
0 -> 1: Event counter
exceeded
1 -> 0: Event counter
exceeded
again
0
-
Comparison state
switching output 4
(Event Counter)
Indicates whether the event counter
has exceeded the set comparative
value.
The bit is reset to the init. value by
resetting the event counter.
1.6
Bit
0: Not exceeded
1: Exceeded
0
-
Switching output 4
Comparison state
toggle bit
(Event Counter)
If "SWOUT switches several times"
was configured as comparison mode,
this bit is toggled each time the event
counter is exceeded.
Indicates whether the event counter
has reached the set comparative
value.
1.7
Bit
0 -> 1: Event counter
exceeded
1 -> 0: Event counter
exceeded
again
0
-
Output data
Description
Addr.
Data type
Value range
Init value Unit
Switching output 1
Sets the state of switching output 1 0.0
Bit
0: Switching output 0
1: Switching output 1
0
-
Switching output 2
Sets the state of switching output 2 0.1
Bit
0: Switching output 0
1: Switching output 1
0
-
Switching output 3
Sets the state of switching output 3 0.2
Bit
0: Switching output 0
1: Switching output 1
0
-
Switching output 4
Sets the state of switching output 4 0.3
Bit
0: Switching output 0
1: Switching output 1
0
-
Reset Event Counter
Switching output 1
Sets the event counter of the activa-
tion function [AF] for switching out-
put 1 back to zero.
0.4
Bit
0 -> 1: Perform reset
1 -> 0: No function
0
-
Reset Event Counter
Switching output 2
Sets the event counter of the activa-
tion function [AF] for switching out-
put 2 back to zero.
0.5
Bit
0 -> 1: Perform reset
1 -> 0: No function
0
-
Reset Event Counter
Switching output 3
Sets the event counter of the activa-
tion function [AF] for switching out-
put 3 back to zero.
0.6
Bit
0 -> 1: Perform reset
1 -> 0: No function
0
-
Reset Event Counter
Switching output 4
Sets the event counter of the activa-
tion function [AF] for switching out-
put 4 back to zero.
0.7
Bit
0 -> 1: Perform reset
1 -> 0: No function
0
-
Reserved
1
Byte
Table 10.50:
Output data for module 74 Input/output status and control
Input data
Description
Addr.
Data type
Value range
Init value Unit
Table 10.49:
Input data for module 74 Input/output status and control (cont.)