Commissioning and configuration
184
BCL 548
i
Leuze electronic
Parameter length
23 byte
Input data
None
Output data
None
Remark
The DC bias level also defines whether the output is low-active (
0
) or high-active (
1
).
Switching on an I/O configured as an output means switching to the active state; switching
off, on the other hand, results in switching to the inactive or idle state.
Reset mode
(Event Counter)
Specifies whether the counter
(Event Counter) is reset only by the
reset bit and the selected switch-
off function, or if the counter
should be automatically reset after
the comparative value is reached.
12
UNSIGNED8
0: Reset bit and
switch-off
funct.
1: Comparative
value
reached
0
-
Mode of operation for configuration as an input
Inversion
The parameter defines the logic of
the incident signal. In case of an
inversion, an external HIGH level is
interpreted internally as a LOW
level.
13.1
Bit
0: Normal
1: Inverted
0
-
Reserved
Free
13.2 … 13.7
Debounce time
The parameter defines a debounce
time which is implemented in soft-
ware.
14
UNSIGNED16
0 … 1000 5
ms
Start-up delay
The parameter influences the tim-
ing during switch-on.
16
UNSIGNED16
0 … 65535
0
ms
Minimum
switch-on time
The parameter defines a minimum
time period before the signal is
reset.
18
UNSIGNED16
0 … 65535
0
ms
Switch-off
delay
The parameter defines a time delay
for the signal during switch-off.
20
UNSIGNED16
0 … 65535
0
ms
Input function
The parameter specifies the func-
tion which is to be activated or
deactivated by a change of state in
the signal.
22
UNSIGNED8
0
-
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Table 10.46:
Parameters for module 71 – Input/Output 2