Commissioning and configuration
160
BCL 548
i
Leuze electronic
10.10 Data Processing
10.10.1 Module 50 – Characteristics filter
PROFINET-IO module identifier
Module-ID 1050
Submodule-ID 1
Description
Configuration of the characteristics filter.
This filter can be used to set how bar codes with identical content are handled and what
criteria are to be taken into account in determining the likeness.
Parameter
Parameter
Description
Addr.
Data type
Value range
Default
Unit
Handling of identical
bar code information
Determines how bar
codes with the same
content are to be man-
aged
0
UNSIGNED8
0: All bar codes are stored and out-
put.
1: Only non-identical bar code con-
tents are output.
1
-
Comparison param-
eter - code type
If this criterion has
been activated, the bar
code type is used to
determine whether the
bar codes are identical.
1.0
Bit
0: deactivated
1: activated
1
-
Comparison param-
eter - bar code con-
tent
If this criterion has
been activated, the bar
code content is used to
determine whether the
bar codes are identical.
1.1
Bit
0: deactivated
1: activated
1
-
Comparison param-
eter - bar code
direction
If this criterion has
been activated, the bar
code direction is used
to determine whether
the bar codes are iden-
tical.
1.2
Bit
0: deactivated
1: activated
1
-
Comparison param-
eter - scan position
If this parameter is not
equal to 0, the bar code
position in the scanning
beam is used to deter-
mine whether identical
bar codes have already
been decoded.
In this case, a +/-
bandwidth in degrees
must be specified,
within which the same
bar code is permitted to
be in the scanning
beam.
2 … 3 UNSIGNED16
0 … 450
0
1/10
degree
Table 10.29:
Parameters for module 50