Commissioning and configuration
Leuze electronic
BCL 548
i
141
TNT
35/7-2
4
V
10.8
Control modules
10.8.1
Module 10 – Activations
PROFINET-IO module identifier
Module-ID 1010
Submodule-ID 1
Description
The module defines the control signals for the reading operation of the bar code reader. It
is possible to select between standard reading operation and handshake operation.
In handshake operation, the controller must acknowledge the data reception via the ACK
bit before the new data is written into the input area.
After acknowledging the last decoding result, the input data is reset (filled with zeros).
Parameter
Parameter length
1 byte
Input data
None
Output data
Parameter
Description
Addr. Data type
Value range
Default
Unit
Mode
The parameter defines the mode in which
the activation module is operated.
0
UNSIGNED8
0:Without ACK
1)
1:With ACK
2)
1)
corresponds to BCL34 module 18
2)
corresponds to BCL34 module 19
0
-
Table 10.7:
Parameters for module 10
Output data
Description
Addr. Data type
Value range
Init value Unit
Reading gate
Signal for activating the read-
ing gate
0.0
Bit
1 -> 0: Reading gate off
0 -> 1: Reading gate active
0
-
Free
0.1
Bit
0
-
Free
0.2
Bit
0
-
Free
0.3
Bit
0
-
Data acknowl-
edgement
This control bit signals that
the transmitted data have
been processed by the mas-
ter.
Only relevant in handshake
mode (with ACK).
0.4
Bit
0 -> 1: Data has been
processed by the
master
1 -> 0: Data has been
processed by the
master
0
-
Table 10.8:
Output data for module 10