Commissioning and configuration
Leuze electronic
BCL 548
i
139
TNT
35/7-2
4
V
10.7.2
Module 5 – Code type features (symbology)
PROFINET-IO module identifier
Module-ID 1005
Submodule-ID 1
Description
The module defines extended features for various code types.
Parameter
Parameter length
6 byte
Input data
None
Output data
None
Parameter
Description
Addr. Data type
Value range
Default
Unit
Maximum width
deviation
Max. permitted width deviation of a
character in percent of the directly
adjacent character.
0
UNSIGNED8
0 … 100
15
%
Code 39 max.
element ratio
Permissible ratio between maximum
and minimum element of Code 39.
1
UNSIGNED8
0 … 255
8
-
Code 39 charac-
ter gap
Permissible ratio for the gap between
two characters for Code 39.
2
UNSIGNED8
0 … 255
3
-
Codabar max.
element ratio
Permissible ratio between maximum
and minimum element of the Codabar
code.
3
UNSIGNED8
0 … 255
8
-
Codabar charac-
ter gap
Permissible ratio for the gap between
two characters for the Codabar code.
4
UNSIGNED8
0 … 255
3
-
Codabar Mon-
arch Mode
The decoding of a Monarch bar code as
Codabar bar code can be switched on
or off.
5.0
Bit
0: Off
1: On
0
-
Codabar start/
stop character
Switches the transmission of a start
and stop character for the Codabar
code on and off.
5.1
Bit
0: Off
1: On
0
-
UPC-E extension
Switches the extension of a UPC-E
code to a UPC-A result on and off.
5.4
Bit
0: Off
1: On
1
-
Code 128: acti-
vate EAN header
Switches the output of the EAN header
on and off.
5.5
Bit
0: Off
1: On
0
-
Code 39 conver-
sion
Defines the conversion method used
for Code 39.
5.6
…
5.7
BitArea
0: Standard (usual con-
version method)
1: Standard ASCII (com-
bination of standard
method and ASCII
method)
2: ASCII (This conversion
method uses the entire
ASCII character set)
0
-
Table 10.5:
Parameters for module 5