Module 34 – Reading reliability (equal scans)
PROFINET-IO module identifier
Module-ID 1034
Submodule-ID 1
Description
The module defines the input data for the communication of the calculated reading reliability.
The value refers to the currently output bar code.
Parameter
None
Input data
Input data length
2 byte consistent
Output data
None
10.9.8
Module 35 – Bar code length
PROFINET-IO module identifier
Module-ID 1035
Submodule-ID 1
Description
The module defines the input data for the communication of the length of the currently output
bar code.
Parameter
None
Input data
Input data length
2 byte consistent
Output data
None
Input data
Description
Addr.
Data type
Value range
Init value Unit
Reading reliability
(Equal scans)
Calculated reading reliability for the
transmitted bar code.
0 … 1
UNSIGNED16
0 … 65535
0
-
Table 10.21:
Input data for module 34
Input data
Description
Addr.
Data type
Value range
Init value Unit
Bar code length
Length/duration of the currently
output bar code, beginning with the
code position specified in module
35 in 1/10 degrees.
0 … 1
UNSIGNED16
1 … 900
1
1/10
degree
Table 10.22:
Input data for module 35