8 Operation
8.1 Minimum Connections
In order to operate the drive you must perform minimum connections. At the very least
you need to connect your PC serial port to the SimpleServo drive. If you also wish to
rotate a motor you must perform minimum system connections. See Section 10 for
various system connections examples. Below is given minimum connection list:
WARNING!
Hazard of electrical shock! Circuit potentials are up to 480 VAC above
earth ground. Avoid direct contact with the printed circuit board or
with circuit elements to prevent the risk of serious injury or fatality.
Disconnect incoming power and wait 60 seconds before servicing
drive. Capacitors retain charge after power is removed.
• Connect serial cable between SimpleServo’s P2 and your PC serial port.
• Connect a Power Cable between an external 120/240 VAC (300-480 VAC for 480
VAC models), 50/60 Hz power source to input power terminal P1.
• Connect motor encoder cable to SimpleServo feedback connector P4 (P11 on
option module if motor equipped with resolver).
• Connect motor windings U, V, W (sometimes called R, S, T) according to Section
5.1.1. Make sure that motor cable shield also connected to PE terminal of P7.
• Provide Enable switch according to Section 8.5.
• Perform drive configuration (see below).
Note
You must configure the drive before it can operate.
Proceed to Section 8.2.
8.2 Configuration of the SimpleServo
Regardless of the mode in which you wish to operate, you must first configure the
SimpleServo for your particular motor, mode of operation, and additional features if
used.
Drive configuration consists of following steps:
• Motor Selection
• Mode of operation selection
• Drive parameters (i.e. current limit, acceleration/deceleration) setup
• Operational limits (velocity or position limits) setup
• Input/Output (I/O) setup
• Velocity / position compensator setup
• Optionally store your settings in the file and exit the program
Содержание SimpleServo 94
Страница 1: ...MODEL 94 USERS MANUAL IMS94S mv1 ...
Страница 12: ...l IMS94S mv1 10 3 2 Clearance for Cooling Air Circulation ...
Страница 56: ...l IMS94S mv1 54 ...
Страница 57: ...IMS94S mv1 l 55 ...
Страница 58: ...l IMS94S mv1 56 ...
Страница 59: ...IMS94S mv1 l 57 ...
Страница 60: ...l IMS94S mv1 58 ...
Страница 61: ...IMS94S mv1 l 59 ...
Страница 62: ...l IMS94S mv1 60 ...
Страница 63: ...IMS94S mv1 l 61 ...
Страница 64: ...l IMS94S mv1 62 ...
Страница 65: ...IMS94S mv1 l 63 ...