Lenze · Decentralised frequency inverter 8400 motec (POWERLINK Option) · EDS84DMOTPL EN 1.0 - 11/2018
27
Commissioning
Node address (node ID) setting
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Setting of the DIP switches DIP1 and DIP2
• The valid address range is 0 ... 239. If the value set via DIP switch DIP2 is higher than 239, the
node ID is set to 239.
• The node ID is used in the last byte of the IP address: 192.168.100.[
Node ID
]
, the DIP switch position of DIP2 (node ID) of the last mains switching is displayed.
, the active node ID is displayed.
•
displays whether the node ID has been set via DIP switches or via
.
DIP switches of the Drive Unit 4 ... 7.5 kW
DIP1
DIP switches for configuring the Drive Unit or for setting the POWERLINK node address
DIP2
DIP1
1
2
3
4
5
6
7
8
Description
OFF
...
...
...
...
...
...
...
The node ID 1 ...239 can be set via DIP2.
(Lenze setting)
ON
...
...
...
...
...
...
...
.
DIP2
1
2
3
4
5
6
7
8
Description
Value
128
64
32
16
8
4
2
1
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF Obtain node ID from
.
(Lenze setting)
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
Node ID = 1
...
...
...
...
...
...
...
...
...
ON
ON
ON
OFF
ON
ON
ON
ON
Node ID = 239
ON
ON
ON
ON
ON
ON
ON
ON
If the set value is higher than 239, the node
ID is set to 239.