Parameter reference
Parameters relevant for POWERLINK communication
56
Lenze · Decentralised frequency inverter 8400 motec (POWERLINK Option) · EDS84DMOTPL EN 1.0 - 11/2018
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13865
C13879
C13880
C13884
Parameter | Name:
C13865 | 0x1F93.2 Node ID by HW
Data type: UNSIGNED_8
Index: 10710
d
= 29D6
h
The code displays whether the EPL node address (node ID) has been set via the DIP switch of the Drive Unit or via
.
• 0 (FALSE): Node ID has been set via
.
• 1 (TRUE): Node ID has been set via DIP switches.
Node address (node ID) setting (
Display range
(min. value | unit | max. value)
0
1
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13879 | Bus error
Data type: UNSIGNED_32
Index: 10696
d
= 29C8
h
The code displays the bus error status which is signalled in the "ERR" LED.
• Bit 0 = 0 (0x00000000) no bus error
• Bit 0 = 1 (0x00000001) bus error active
Value is bit-coded:
Bit 0 Bus Error if TRUE
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13880 | error response
Data type: UNSIGNED_8
Index: 10695
d
= 29C7
h
The subcodes determine the reaction when the OPERATIONAL state is left, when SoC is lost and when a CRC error
occurs.
Selection list
0 No response
1 Error
3 Quick stop by trouble
4 Warning Locked
6 Information
Subcodes
Lenze setting
Info
C13880/1
0: No Response
Error reaction at OPERATIONAL loss
C13880/2
0: No Response
Error reaction at SoC loss
C13880/3
0: No Response
Error reaction at CRC error
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT
Parameter | Name:
C13884 | Response to RPDO monitoring
Data type: BITFIELD_8
Index: 10691
d
= 29C3
h
The code displays if the EPL node is synchronised.
• Bit 0 = 0 (0x00000000) The EPL node is not synchronised.
• Bit 0 = 1 (0x00000001) The EPL node is synchronised.
Value is bit-coded:
Bit 0 CU Synchronisation is locked if TRUE
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT