Parameter reference
Parameters relevant for POWERLINK communication
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C13060
Parameter | Name:
C13060 | 0x1006 Cycle Time
Data type: UNSIGNED_32
Index: 11515
d
= 2CFB
h
The code declares the length of the EPL cycle in
μ
s.
• In the configured state, this code must have an identical value in all EPL nodes.
• The selected value must correspond to the actual bus cycle time so that the internal monitoring functions work
correctly.
Selection list
(Lenze setting printed in bold)
400 400
500 500
600 600
800 800
1000 1000
2000 2000
3000 3000
4000 4000
5000 5000
6000 6000
7000 7000
8000 8000
9000 9000
10000 10000
11000 11000
12000 12000
13000 13000
14000 14000
15000 15000
16000 16000
17000 17000
18000 18000
19000 19000
20000 20000
Read access
Write access
CINH
PLC-STOP
No transfer
PDO_MAP_RX
PDO_MAP_TX
COM
MOT