![Lenze 8200 vector E82CV153K4B Скачать руководство пользователя страница 178](http://html1.mh-extra.com/html/lenze/8200-vector-e82cv153k4b/8200-vector-e82cv153k4b_mounting-instructions_1882275178.webp)
Commissioning
Important codes for quick commissioning
178
EDK82EV903 DE/EN/FR 5.1
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0002*
uSEr
(Continua
tion)
Loading/copying
the own basic
setting
By using this function you can also
just copy PAR1 into the parameter
sets PAR2 ... PAR4
5
own basic setting
ð
PAR1
Restore own basic setting in the
parameter set selected
6
own basic setting
ð
PAR2
7
own basic setting
ð
PAR3
8
own basic setting
ð
PAR4
C0003*
Saving
parameters
non−volatilely
1
0
Do not save parameters in the EEPROM
Data loss after mains switch−off
1
Always save parameters in the EEPROM
l
Active after every mains
connection
l
Cyclic alteration of parameters via
bus module is not permissible
3
Save your own basic setting in the EEPROM Afterwards save parameter set 1 as
own basic setting with C0002 = 9
C0007
uSEr
Fixed
configuration
digital inputs
Change of C0007 is copied into the
corresponding subcode of C0410. Free
configuration in C0410 sets
C0007 = 255!
0
E4
E3
E2
E1
l
CW/CCW = clockwise
rotation/counter−clockwise
rotation
l
DCB = DC injection brake
l
QSP = quickstop
l
PAR = change over parameter set
(PAR1
ó
PAR2)
– PAR1 = LOW, PAR2 = HIGH
– The terminal in PAR1 and PAR2
has to be assigned with the
"PAR" function.
– Only use configurations with
"PAR" if C0988 = 0
l
TRIP−Set = external error
0
CW/CCW
DCB
JOG2/3
JOG1/3
1
CW/CCW
PAR
JOG2/3
JOG1/3
2
CW/CCW
QSP
JOG2/3
JOG1/3
3
CW/CCW
PAR
DCB
JOG1/3
4
CW/CCW
QSP
PAR
JOG1/3
5
CW/CCW
DCB
TRIP−Set
JOG1/3
6
CW/CCW
PAR
TRIP−Set
JOG1/3
7
CW/CCW
PAR
DCB
TRIP−Set
8
CW/CCW
QSP
PAR
TRIP−Set
9
CW/CCW
QSP
TRIP−Set
JOG1/3
10
CW/CCW
TRIP−Set
UP
DOWN
C0007
uSEr
(Continua
tion)
E4
E3
E2
E1
l
Selection of fixed
setpoints
JOG1/3
JOG2/3
LOW LOW
HIGH LOW
LOW HIGH
HIGH HIGH
Active
C0046
JOG1
JOG2
JOG3
11
CW/CCW
DCB
UP
DOWN
12
CW/CCW
PAR
UP
DOWN
13
CW/CCW
QSP
UP
DOWN
14
CCW/QSP
CW/QSP
DCB
JOG1/3
15
CCW/QSP
CW/QSP
PAR
JOG1/3
16
CCW/QSP
CW/QSP
JOG2/3
JOG1/3
17
CCW/QSP
CW/QSP
PAR
DCB
18
CCW/QSP
CW/QSP
PAR
TRIP−Set
19
CCW/QSP
CW/QSP
DCB
TRIP−Set
Содержание 8200 vector E82CV153K4B
Страница 3: ...E82EV153K4B E82EV303K4B 8200vec292 E82EV453K4B E82EV553K4B 8200vec311...
Страница 97: ...Fehlersuche und St rungsbeseitigung St rungsmeldungen zur cksetzen 8 97 EDK82EV903 DE EN FR 5 1...
Страница 285: ......
Страница 286: ...E82EV753K4B E82EV903K4B 8200vec312...
Страница 287: ......