Electrical installation
Important notes
5
138
EDK82EV903 DE/EN/FR 5.1
5
Electrical installation
5.1
Important notes
Danger!
Dangerous electrical voltage
Terminals can carry dangerous electrical voltage − also if the motor is stopped
or after the mains is switched off!
Possible consequences:
ƒ
Death or severe injuries when touching live terminals.
Protective measures:
Before all operations on the controller
ƒ
Switch off the mains voltage and wait for at least 3 minutes.
ƒ
Check whether terminals are isolated from supply, since
– the power terminals U, V, W, +UG, −UG, BR1, BR2, and the pins of the FIF
interfaces still carry dangerous voltage for at least 3 minutes after
power−off.
– the power terminals L1, L2, L3; U, V, W, +UG, −UG, BR1, BR2, and the pins of
the FIF interfaces carry dangerous voltage when the motor is stopped.
– the relay outputs K11, K12, K14 can carry dangerous voltage when the
drive controller is disconnected from the mains.
Stop!
Short circuit and static discharge
The device contains components that can be damaged in case of a short circuit
or static discharge.
Possible consequences:
ƒ
The device or parts of it are destroyed.
Protective measures:
ƒ
Always switch off the voltage supply when working on the device. This must
be especially observed in the following cases:
– Before opening the housing.
– Before connecting/disconnecting connectors.
– Before plugging in / removing modules.
ƒ
Before working on the device, the personnel must be free of electrostatic
charge.
ƒ
Do not touch the contacts.