Mechanical installation
Standard devices with a power of 55 kW
Mounting with fixing brackets (standard)
130
EDK82EV903 DE/EN/FR 5.1
Dimensions [mm]
8200 vector
a
b
b1
c
c1
d
d1
e
1)
g
k
m
E82EV553K4B2xx
340
672
591
28.5
283
615
38
285
11
28
18
1)
If the function module is attached: observe mounting clearance and cable bending radius. The terminals of function
modules in PT design protrude above the housing by 8 mm.
Controller variant "3xx" (with fully mounted footprint filter)
For this mounting variant you require controller type E82
E
VxxxK4B
3xx
.
a
c1
b
d
d1
l
c
³
50 mm
³
50 m
g
m
k
0
³
100 mm
³
100mm
e
8200vec298
Loosen both screws to be able to remove the housing cover. The assembly kit is located under
the housing cover.
Installation of mounting angles
Dimensions
Arrange the controllers side by side with spacing to be able to disassemble the eyebolts.
Dimensions [mm]
8200 vector
integr. mains
filter
2)
a
b
b1
c
c1
d
d1
d2
e
1)
g
k
m
E82EV553K4B3xx
E82ZN55334B230
340
729
591
283 28.5 672
38
615
375
11
28
18
1)
If the function module is attached: observe mounting clearance and cable bending radius. The terminals of function
modules in PT design protrude above the housing by 8 mm.
2)
The integrated mains filters are only designed for controller operation at rated power. Different filters with different
dimensions are possible (