155
1
Status
01h – Turn on fault led
00h – Turn off fault led (Fault led mask will be automatically set to 0x00 to mask all of errors,
user needs to use command 0x12 to set mask to 0xff again so that fault led will works as normal,
see detail in command “Set Fault Led Mask”)
Response Data:
Byte
Data field
1
Completion Code
2
Status
01h: Fault led is turned on
00h: Fault led is turned off
2.16 Get Fault LED Status
This is the command to get fault led status.
Linux command:
$ ipmitool raw 0x3c 0x11
Description:
NetFn
0x3c
Command
0x11
Request Data:
Byte
Data field
NONE
NONE
Response Data:
Byte
Data field
1
Completion Code
2
Status
01h: Fault led is currently on 00h:
Fault led is currently off
2.17 Set Fault LED Mask
This is the command to set fault led mask to enable/disable the error affects fault led.
Linux command:
$ ipmitool raw 0x3c 0x12
Description:
Содержание ThinkSystem HR350A
Страница 37: ...37 ...
Страница 55: ...55 3 4 7 2 PCI Express GEN 2 Settings ...
Страница 59: ...59 ...
Страница 62: ...62 ...
Страница 66: ...66 Entering this menu item will allow users to configure the device parameters ...
Страница 71: ...71 Patrol Scrub Enable disable Patrol Scrub for DDR controller ...
Страница 85: ...85 3 9 3 View FRU Information ...
Страница 89: ...89 ...
Страница 90: ...90 3 9 6 BMC User Settings This section allows users to Add Delete and Set Privilege levels for BMC users ...
Страница 97: ...97 Figure 2 Configuring IE ESC step 2 Figure 3 Configuring IE ESC step 3 ...
Страница 107: ...107 4 9 3 Event Log 4 9 4 Images Redirection This page is used to configure the images into BMC for redirection ...
Страница 115: ...115 4 9 19 Virtual Media 4 9 20 IPMI Configuration 4 10 Remote Control This page is used to launch KVM ...
Страница 118: ...118 3 Select Restore Configuration and upload the downloaded backup files ...
Страница 120: ...120 ...
Страница 123: ...123 Select OK to continue ...